欢迎访问ic37.com |
会员登录 免费注册
发布采购

SL120 参数 Datasheet PDF下载

SL120图片预览
型号: SL120
PDF下载: 下载PDF文件 查看货源
内容描述: 单路输出115/230 VAC输入输出浮动 [Single output 115/230 VAC input Floating output]
分类和应用:
文件页数/大小: 2 页 / 53 K
品牌: ARTESYN [ ARTESYN TECHNOLOGIES ]
 浏览型号SL120的Datasheet PDF文件第2页  
SL120 and SL220 SERIES
Single output
SL120: For new design-ins see the NFS110 Series instead
SL220: For new design-ins see the NFS200 and LX200 Series instead
115/230 VAC input
UL, CSA and (VDE approved - SL120 only)
Short circuit protection
Floating output
20ms hold-up time min.
This series of 100 Watt to 220 Watt single output switchers use an advanced
circuit topology providing superior performance at low cost. Smaller and lighter
than equivalent linear supplies, they are available in 5V and 24V output versions.
The floating outputs can be referenced as either positive or negative. The SL120
model is UL, CSA and VDE approved. Also, selected models incorporate remote
sense. SL120/220 Series power supplies are suitable for a wide variety of
applications, including front end power systems, general industrial and telecom
equipment.
[ 2 YEAR WARRANTY ]
SL120 only
SPECIFICATION
OUTPUT SPECIFICATIONS
Output voltage
adjustability
Line regulation
Load regulation
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
GENERAL SPECIFICATIONS
4.5V to 5.5V
18V to 26V
±0.2%
±2.0%
±1.0%
None
Efficiency
Isolation voltage
SL220
SL220
SL120
SL120
Input/Output
Input/Chassis
Input/Output
Input/Chassis
Hold-up Time
Low line, full load
SL120, 110VAC
SL120, 230VAC
SL220, 110VAC
SL220, 230VAC
36ms
36ms
20ms
20ms
65%, max.
1500VAC
1500VAC
3750VAC
1500VAC
5V Models
24V Models
LL to HL, FL
60% FL, ±40%
SL120
SL220
At turn-on
SL120: +5V (12A to 20A)
Overshoot/undershoot
Transient response
±300mV,
1ms recovery
SL220: +5V (10A to 20A)
±100mV,
1ms recovery
±0.03%/°C
±0.05%/°C
6.25 ±0.75V
130W min.
260W min.
Yes
Approvals and
standards
Weight
MTBF
Safety: SL120 series
VDE0805,
EN60950, UL478
CSA bulletin No. 1402C
1.2kg (42.4oz)
2.3kg (81.2oz)
25,000 hours min.
50,000 hours min.
Temperature coefficient SL120, all outputs
SL220, all outputs
Overvoltage protection
Output power limit
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Maximum input
surge current
Safety ground
leakage current
User Selectable
5V output
SL120
SL220
SL120
SL220
SL120
SL220
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Relative humidity
Altitude
Operating, See Note 8
0°C to +70°C
Non-operating
–40°C to +85°C
Non-condensing
Operating
Non-operating
5% to 80% RH
10,000 feet max.
30,000 feet max.
85 to 132VAC
170 to 264VAC
47Hz to 440Hz
SL120: 230VAC, cold start
SL220: 230VAC, cold start
230VAC Input, 50Hz
22A
74A
0.7mA
PAGE 1