 浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第2页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第3页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第4页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第5页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第6页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第7页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第9页浏览型号WS12-1250-ADSI16-L25的Datasheet PDF文件第10页  
Output Specification  
ADSI16 for WS position sensors  
· Resolution 16 bit, data transmission synchronous serial/SSI  
· Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution  
· No loss of data at power-down  
· Easy to connect to PLCs with SSI input circuit  
The sensing device of the ADSI is a precision potentiometer. The position information is  
given by an analog/digital converter output serialized as a data word. Data transmission  
takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Micro-  
computer) sends pulse sequences which clock the data transmission with the required  
transfer rate. With the first falling edge of a pulse sequence the position of the sensor is  
recorded and stored. The following rising edges control the bit-by-bit A/D conversion,  
encoding and output of the data word. After a delay time the next new position information  
will be transmitted.  
Description  
Data Format  
(Train of 26 Pulses)  
Output  
EIA RS-422, RS-485, short-circuit proof  
11 ... 27 VDC  
Signal Conditioner  
ADSI  
Excitation voltage  
Excitation current  
Clock frequency  
Code  
200 mA max.  
70 ... 500 kHz  
A/D converted  
synchronous serial  
Gray code, continuous progression  
T=30 µs min.  
Delay between pulse trains  
Resolution  
16 bit (65536 counts) full scale; optional 12 bit  
or 14 bit  
Stability (temperature)  
Operation temperature  
EMC  
50 x 10-6 / °C full scale  
-20 ... +85 °C  
According to EN 61326:2004  
Sensor circuit  
Cable  
Subsequent circuit  
Recommended  
Processing  
Input Circuit  
GND (0V)  
Cable length  
Baud rate  
Note:  
Transmission rate  
Signal Wiring  
Extension of the cable length will reduce the  
maximum transmission rate. The signals  
CLOCK/CLOCK and DATA/DATA must be  
connected in a twisted pair cable, shielded  
per pair and common.  
< 50 m  
< 300 kHz  
< 100 kHz  
< 100 m  
Signal names  
Connector pin no.  
Mating connector: view to solder terminals  
Excitation +  
Excitation GND (0V)  
CLOCK  
1
2
3
CLOCK  
4
DATA  
5
DATA  
6
Screen  
not connected  