欢迎访问ic37.com |
会员登录 免费注册
发布采购

WS17KT-12500-420T-L05 参数 Datasheet PDF下载

WS17KT-12500-420T-L05图片预览
型号: WS17KT-12500-420T-L05
PDF下载: 下载PDF文件 查看货源
内容描述: 模拟或SSI输出 [analog or SSI output]
分类和应用:
文件页数/大小: 8 页 / 243 K
品牌: ASM-SENSOR [ ASM GMBH ]
 浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第1页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第2页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第3页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第4页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第5页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第6页浏览型号WS17KT-12500-420T-L05的Datasheet PDF文件第7页  
Output Specification
ADSI16 for WS position sensors
·
·
·
·
Description
Resolution 16 bit, data transmission synchronous serial/SSI
Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution
No loss of data at power-down
Easy to connect to PLC’s with SSI input circuit
The sensing device of the ADSI is a precision potentiometer. The position information is
given by an analog/digital converter output serialized as a data word. Data transmission
takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Micro-
computer) sends pulse sequences which clock the data transmission with the required
transfer rate. With the first falling edge of a pulse sequence the position of the sensor is
recorded and stored. The following rising edges control the bit-by-bit A/D conversion,
encoding and output of the data word. After a delay time the next new position information
will be transmitted.
Data Format
(Train of 26 Pulses)
Signal Conditioner
ADSI
A/D converted
synchronous serial
Output
Excitation voltage
Excitation current
Clock frequency
Code
Delay between pulse trains
Resolution
Stability (temperature)
Operation temperature
EMC
EIA RS-422, RS-485, short-circuit proof
11 ... 27 VDC
200 mA max.
70 ... 500 kHz
Gray code, continuous progression
T=30 µs min.
16 bit (65536 counts) full scale; optional 12 bit
or 14 bit
±50 x 10
-6
/ °C full scale
-20 ... +85 °C
According to EN 61326:2004
Recommended
Processing
Input Circuit
Sensor circuit
Cable
Subsequent circuit
GND (0V)
Cable length
Baud rate
< 300 kHz
< 100 kHz
Transmission rate
< 50 m
< 100 m
Note:
Extension of the cable length will reduce the
maximum transmission rate. The signals
CLOCK/CLOCK and DATA/DATA must be
connected in a twisted pair cable, shielded
per pair and common.
Mating connector: view to solder terminals
Signal names
Connector pin no.
1
2
3
4
5
6
not connected
Signal Wiring
Excitation +
Excitation GND (0V)
CLOCK
CLOCK
DATA
DATA
Screen
CONN-DIN-8F-W
CONN-M12-8F-G
ASM
64
CAT-WS-E-05
www.asm-sensor.com