A PA 0 6 N o n - I s o l a t e d P o w e r S I P s
3V-5.5V Input, 1.2V-3.3V Output, 9-20W Output
output also grounded.
3. Any non-SELV input must be provided with
reinforced from any other hazardous voltages,
including the ac mains, and must have a SELV
reliability test performed on it in combination
with the converters. Inputs must meet SELV
requirements.
If the input meets extra-low voltage (ELV)
requirements, then the converter's output is
considered ELV.
The input to these units is to be provided
with a maximum 10A normal blow fuse in
the ungrounded lead.
APA06G05(E-6) and APA6F05(E-6) need 15A
fuse.
Mechanical Considerations
Thermal Performance
APA06 series will derate at 55°C under the
condition of 200LFM. In order to maintain effi-
cient heat dissipation, the converters should be
mounted parallel with the air-flow direction.
Soldering
APA06 series converters are compatible with
standard wave soldering techniques. When
wave soldering, the converter pins should be
preheated for 20-30 seconds at 110° C, and
wave soldered at 260°C for less than 10 sec-
onds.
When hand soldering, the iron temperature
should be maintained at 425°C and applied to
the converter pins for less than 5 seconds.
Longer exposure can cause internal damage to
the converter. Cleaning can be performed with
cleaning solvent IPA or with water.
Recommended Hole Pattern
Dimensions are in millimeters (inches). Component-side footprint.
63.5 (2.50)
7.1
(0.28)
2.54
(0.100)
J1-1
J2-6
Keep Out
1.17 (0.046) Plated-through Hole
1.78 (0.070) Pad Size Both Sides
9.1
(0.36)
Max. height
48.3 (1.90)
2.79 8.38
(0.110)(0.33)
Fig.6 Recommended Hole Pattern
Mechanical Chart (Figure 7-9 next page)
TEL:
FAX:
USA
1-760-930-4600
1-760-930-0698
Europe
44-(0)1384-842-211
44-(0)1384-843-355
Asia
852-2437-9662
852-2402-4426
-12-