Technical Reference Note (APC08)
Electrical Specifications
STANDARD TEST CONDITION
on a single unit, unless otherwise specified.
T
A
:
25°C (Ambient Air)
Vin (P1):
APC08x03
+1.8V to +6.0V
APC08x08
+5.0V to +13V
Enable (P5):
Open
Vo (P2):
Connect to load
Gnd (P3):
Return for Vin and Vo
Trim (P4):
Open
PGood (P6):
Open
P (P7):
Open
ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation
of the device is not implied at these or in any other conditions in excess of those given in the operational sections of
the specs. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Input Voltage
Continuous
Transient (100ms)
Continuous
Transient (100ms)
Operating Temperature
Storage Temperature
Operating Humidity
Device
03
03
08
08
All
All
All
Symbol
V
IN
V
IN,trans
V
IN
V
IN,trans
T
A
T
STG
-
Min
1.8
-
5.0
-
-40
-40
-
Typ
-
-
-
-
-
-
-
Max
6.0
7.0
13.0
14.0
85
125
85
Unit
Vdc
Vdc
Vdc
Vdc
ºC
ºC
%
INPUT SPECIFICATIONS
Parameter
Operating Input Voltage
1
Maximum Input Current
2
(V
IN
= 0 to V
IN,max
; I
O
= I
O,max
)
Input Ripple Current
5Hz to 20MHz
Device
03
08
All
APC05
APC04
All
Symbol
V
IN
I
IN,max
I
IN-1
Min
1.8
5.0
-
Typ
3.3
8.0
-
-
200
Max
6.0
12.0
9.0
6.0
5.0
250
Unit
Vdc
Vdc
A
mAp-p
Note: 1. Minimum V
IN
(03 device) for 1V8, 2V5 and 3V3 versions are 2V2, 3V and 4V respectively. For 08
device, min V
IN
for 5V and 6V versions are 7.5Vin and 8.5Vin
2. This power module is not internally fused. The use of an input line fuse (03 Version: GMA-10A; 08
version: GMA-6A Bussman fuses or equivalent) is recommended.
MODEL: APC08 SERIES
OCTOBER 4, 2004 - REVISION 03
SHEET 3 OF 23