Technical Reference Notes (TRN)
BK60C-H Series
36 Vdc to 75 Vdc Inputs, 150 W
Electrical Specifications
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device.
These are absolute stress ratings only. Functional operation of the device in not implied at these
or any other conditions in excess of those given in the operational sections of the TRN. Exposure
to absolute maximum ratings for extended periods can adversely affect device reliability.
Table 1. Absolute Maximum Ratings
Parameter
Device
Input Voltage:
Continuous:
All
Transient (100ms)
All
Operating Case Temperature
All
Storage Temperature
All
Operating Humidity
All
I/O Isolation
All
Symbol
V
I
V
I, trans
Tc
Tstg
-
-
Min
0
0
-40
-55
-
-
Typ
-
-
-
-
-
-
Max
80
100
100
125
95
1500
Unit
Vdc
Vdc
ºC
ºC
%
Vdc
Input Specifications
Table 2. Input Specifications
Parameter
Operating Input Voltage
Maximum Input Current
(V
I
= 0 to V
I,max
: Io = Io,max)
Input Reflected-ripple Current
(
5Hz to 20MHz: 12uH source
impedance: T
A
= 25 ºC.) See Figure 9.
Device
All
018FX
025FX
033FX
All
All
All
Symbol
V
I
I
I,max
I
I,max
I
I,max
I
I
-
-
Min
36
-
-
-
-
-
-
Typ
48
-
-
-
10
-
-
Max
75
3.0
4.0
5.0
-
7.5
3.7
Unit
Vdc
A
A
A
mAp-p
W
uF
No Load Input Power
(V
I
= V
I,nom
)
Internal Input Capacitance
Output Specifications
Table 3. Output Specifications
Parameter
Output Voltage Setpoint
(V
I
= V
I,min
to V
I,max
: Io = Io,max;
T
A
= 25 ºC )
Device
018FX
025FX
033FX
Symbol
Vo,set
Vo,set
Vo,set
Min
1.77
2.46
3.25
Typ
1.8
2.5
3.3
Max
1.83
2.54
3.35
Unit
Vdc
Vdc
Vdc