欢迎访问ic37.com |
会员登录 免费注册
发布采购

LPX80 参数 Datasheet PDF下载

LPX80图片预览
型号: LPX80
PDF下载: 下载PDF文件 查看货源
内容描述: 围墙 [ENCLOSURE]
分类和应用: 瞄准线
文件页数/大小: 1 页 / 742 K
品牌: ASTEC [ Astec America, Inc ]
   
LPX 80
ENCLOSURE
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: +44(0)1384-842211
Facsimile: +44(0)1384-843355
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384)842-211
Facsimile: 44 (1384) 843-355
Installation Notes
LPX80 • Cover Enclosure Kit
LPX80 will fit all the LPX8X power supplies
(2X) M3 INSERTS
INPUT
WIRING
ACCESS
1.181 [ 30.0 ]
0.984 [ 25.0 ]
1.134 [ 28.8 ]
OUTPUT TERMINALS
2.236 [ 56.8 ]
3.858 [98.0 ]
OUTPUT
WIRING ACCESS
5.906 [150.0 ]
INPUT TERMINALS
INSULATOR
1.748 [44.4 ]
(2X) 0.591 [15.0 ]
(2X) M3 INSERTS
(2X) 4.331 [110.0 ]
(2X) 0.787 [20.0 ]
(2X) 0.364 [ 9.3 ]
(2X) 0.787 [ 20.0 ]
(2X) Ø4mm MTG HOLES
(2X) 4.803 [122.0 ]
(2X) 3.543 [90.0 ]
(2X) 0.738 [ 18.8 ]
(4X) M3 STANDOFF
FOR MTG POWER SUPPLY
A
(2X) 2.55 [65 ]
(4X) STANDOFF
A
GROUND STUD
(2X) 3.150 [80.0 ]
(2X) 2.756 [70.0 ]
0.25 [6.4]
Ø0.35 [Ø8.8]
Ø0.14 [Ø3.6]
(2X) 0.354
[ 9.0 ]
A
A
(2X) 0.657 [ 16.7 ]
(2X) 0.551 [ 14.0 ]
M3 INSERTS
(4X) MARKED "A"
SEE KEYWAY DETAILS
MATERIALS
1
1
4
4
1
1
1
1
Base
Cover
M3 x 6mm pan head screws with spring washer
M3 x 6mm countersunk sdrews
M4 nut
M4 star washer
M4 spring washer
Plastic insulator sheet
NOTES
1.
2.
3.
All dimensions are in inches (mm)
Overall dimensions:
5.9 (150) x 3.9 (98.0) x 1.75 (44.4)
Base plate has three sets of customer mountings:
a. Bottom mounting (4x) M3 inserts. Max. screw penetration 0.0787 (2mm)
b. Bottom mounting (2x) 4mm clear holes plus 2 keyways (see keyway detail)
c. Side mountings (4x) M3 inserts. Max. screw penetration 0.236 (6mm)
Ensure insulator is correctly fitted in base under PCB to maintain safety creepage and
clearances.
Ensure base is firmly connected to supply earth via the earth stud marked
.
When using this enclosure, ensure that relevant safety standards (e.g., EN60950) are
complied with, in respect to creepage and clearance distances, and distances through
insulation.
4.
5.
6.
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 8.25.04