欢迎访问ic37.com |
会员登录 免费注册
发布采购

NTS353 参数 Datasheet PDF下载

NTS353图片预览
型号: NTS353
PDF下载: 下载PDF文件 查看货源
内容描述: 350瓦 [350 Watts]
分类和应用:
文件页数/大小: 2 页 / 345 K
品牌: ASTEC [ Astec America, Inc ]
 浏览型号NTS353的Datasheet PDF文件第2页  
350 Watts
Total Power:
Input Voltage:
# of Outputs:
NTS350 Series
200-350 Watts
85-264 VAC
120-300 VDC
Single
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
85-264 VAC; 120-300 VDC
47-440 Hz
38 A max., cold start @ 25°C
85% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and
radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
Power factor
Safety ground
leakage current
Special Features
Active power factor correction
IEC EN6100-3-2 compliance
Remote sense
Power fail and remote inhibit
Single wire current sharing
Built-in EMI filter
Low output ripple
5V standby
12V fan output
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
Built in OR-ing diode / FET
Optional fan cover (-CF suffix)
Output
Maximum power
Adjustment range
Standby output
Fan output
Hold-up time
Overload protection
200W convection; 350 W with 30 CFM
forced air
±5%
5 V @ 2A regulated, ±5%
12 V @ 1A, -5 %, +7%, 0.5A for -CF version
20 ms @ 350 W load, 115 VAC nominal
line at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 115-130%
above peak rating
20% to 35% above nominal output
Overvoltage protection
Logic Control
Power failure
TTL logic signal goes high 100-500 msec
after main output. It goes low at least 4
msec before loss of regulation
Requires an external contact closure to
inhibit outputs
TTL logic goes high after the output is in
regulation. It goes low when there is loss
of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection protected.
Remote on/off
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -4, -5, -11 Level 3
Humidity: Operating; non-condensing
10% to 90%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
2 G peak 8 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >1M hours at full load and
25°C ambient conditions
DC OK
Remote sense
Safety
TUV
UL
CSA
NEMKO
AUSTEL
CB
CE
60950
60950
60950
60950
60950
Certificate and report
Mark (LVD)
1
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.19.05