Isolated and Regulated 1.5 WATT Modular DC/DC Converters  
asd105 erieꢀ  
INPUT sPECIFICaTIONs  
ENVIRONMENTaL sPECIFICaTIONs  
Input Voltage Ranges:  
5 VDC Nominal  
12 VDC Nominal  
24 VDC Nominal  
28 VDC Nominal  
48 VDC Nominal  
PI Type  
4.5-5.5 VDC  
10.8-13.2 VDC  
21.6-26.4 VDC  
25.2-30.8 VDC  
43.2-52.8 VDC  
Oper. Temperature  
Case Temperature  
Storage Temperature  
Cooling  
-25 to +71°C  
100°C max.  
-40 to +100°C *  
Free Air Convection  
MTBF  
Single O/P  
1,024,000 Hrs.  
937,000 Hrs.  
Input Filter  
Dual O/P  
MIL-HDBK-217F  
Ground Benign, 25°C  
OUTPUT sPECIFICaTIONs  
Voltage and Current  
Load Regulation  
See Selection Chart  
20% to FL  
PHYsICaL sPECIFICaTIONs  
+/- 0.5%  
Line Regulation (HL-LL)  
Temperature Coefficient  
Ripple/Noise(Single/Dual)  
Voltage Accuracy  
+/- 0.3%  
Case Material  
Black coated Copper  
+/-0.02%/°C  
50mVp-p max.  
+/- 4%  
w. Non-conductive base  
Fully Encapsulated  
0.5 oz, (13g)  
Construction  
Weight  
Short Circuit Protection  
Efficiency  
1 second max.  
50%  
Dimensions  
1.25” x 0.8” x 0.4”  
GENERaL sPECIFICaTIONs  
Input-Output Isolation  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
500VDC  
10-9nth Ohm min.  
30pF  
20Khz  
All specifications are typical at nominal input, full load, and 25°C unless other-  
wise noted  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
300 Myleꢀ stꢁnꢂiꢀh Blvꢂ., Tꢁunton, Ma 02780  
WWW.asTROdYNE.COM  
Ph: 1-800-823-8082  
Fꢁx: 508-823-8181