Features
Universal AC�½input�½/�½Full�½range
Low�½leakage�½current�½<180 A
Protections:Short�½circuit/Over�½load/Over�½voltage
UL2601-1�½medical�½safety approved
With�½power�½good�½and�½fail�½signal�½output�½(Optional)
100%�½full�½load�½burn-in�½test
Fixed�½switching�½frequency�½at�½45KHz
3�½years�½warranty
Specification
AC�½INPUT�½VOLTAGE
90~264�½VAC,�½47~440Hz�½/�½127~370VDC.
AC�½INPUT�½CURRENT
(Typ.)
Maximum�½input�½current�½2.9A at�½115VAC,�½60Hz�½or
1.7A at�½230VAC,�½60Hz�½with�½100%�½output�½load.
INRUSH�½CURRENT
(Typ.)
Inrush�½current�½is�½less�½than�½22A at�½115VAC�½or�½less�½than
45A at�½230VAC�½under�½cold�½start�½conditions.�½Limiting
provided�½by�½internal�½thermistors.
SETUP,�½RISE�½TIME
MPS-120:
800ms,�½20ms�½/�½230VAC�½at�½full�½load
2000ms,�½50ms�½/�½115VAC�½at�½full�½load
MPD,T,Q-120:500ms,�½20ms�½/�½230VAC�½at�½full�½load
1200ms,�½50ms�½/�½115VAC�½at�½full�½load
HOLD-UP TIME
(Typ.)
80ms�½/�½230VAC�½at�½full�½load
16ms�½/�½115VAC�½at�½full�½load
LEAKAGE�½CURRENT
Leakage�½current�½is�½less�½than�½180 A at�½264VAC
DC�½OUTPUT ADJ.�½RANGE
DC�½output�½voltage�½(or�½Ch1�½of�½multiple�½output�½models)
can�½be�½adjusted�½between�½-5%~+10%�½rated�½output
voltage�½by�½potential�½meter.
OVER�½LOAD�½PROTECTION
Fully�½protected�½against�½short�½circuit�½and�½output�½overload.
The�½hiccup�½type�½protection will�½be�½activated�½at�½110~150%
(For�½MPD,T,Q-120),120~160%(For�½MPS-120)�½rated�½load
and�½recovers�½automatically�½after�½fault�½condition�½is removed.
OVER�½VOLTAGE�½PROTECTION
Provided�½on�½output�½channel�½1�½only�½at�½115%~135%
rated�½output�½voltage.�½(120%~140%�½for�½MPS-120-15/24/48).
Output�½will�½be�½shut�½down�½when�½this�½protection�½is�½activated.
POWER�½GOOD�½/�½FAIL SIGNAL (OPTIONAL)
TTL logic�½high�½for�½power�½good�½and TTL low�½for
power�½fail.�½When�½the�½output�½voltage�½reaches�½90%�½of
rated�½value,�½a�½+5V TTL signal�½will�½be�½sent�½out�½with�½a
10~500ms�½delay; At�½least�½1ms�½before�½the�½output
voltage�½goes�½below�½90%�½of�½the�½rated�½value,�½the TTL
signal�½will�½be�½turned�½off.
*�½MPS-120-3.3�½does�½not�½have�½this�½optional�½function.
WORKING�½TEMP.
Whole�½series�½can�½operate�½from�½-20~70
to�½the�½derating�½curves.
WORKING�½HUMIDITY
20~90%�½RH�½non-condensing.
.�½Please�½refer
TEMP.�½COEFFICIENT
0.04%/ on�½all�½outputs�½at�½full�½load�½between�½0~50
of�½ambient�½temperature.
VIBRATION
2G�½of�½acceleration,�½vibrating�½frequency�½adjust�½from�½10Hz�½~500Hz�½within�½a
10-minute�½cycle.�½6�½testing�½cycles�½(60�½minutes)�½each�½along�½X, Y,�½Z�½axes.
SAFETY STANDARDS
Medical
:
UL2601-1, TUV�½EN60601-1�½approved
Commercial�½: Also�½design�½refer�½to�½UL60950-1, TUV�½EN60950-1
WITHSTAND�½VOLTAGE
4000VAC�½between�½input�½and�½output
1500VAC�½between�½input�½and�½F.G.
500VAC�½between�½output�½and�½F.G.
ISOLATION�½RESISTANCE
>100M�½Ohms�½for�½I/P-O/P,�½I/P-FG,�½O/P-FG�½by�½using�½500VDC�½test�½voltage.
EMI�½COMPLIANCE
EMI�½Specifications
Conducted�½&�½Radiation
Harmonic�½distortion
Voltage�½flicker
EMS�½COMPLIANCE
EMS�½Specification
ESD�½air
ESD�½contact
RF�½field�½susceptibility
EFT(Electrical�½Fast Transient)/Burst
Lightning/Surge
Conducted�½RF�½susceptibility
Magnetic�½field�½immunity
Voltage�½dip,�½interruption
Digital�½phone�½carrier�½immunity
MTBF
262,100�½hours�½min.�½at�½full�½load�½and�½25
calculated�½per�½MIL-HDBK-217F.
DIMENSION�½(L*W*H)
177.8x107.95x35.5mm�½or�½7"x4.25"x1.4"
PACKING
0.55Kg;�½24pcs/14.5Kg/1.04CUFT
Compliance�½Level
EN55011,�½Class�½B
EN55022,�½Class�½B
EN61000-3-2
EN61000-3-3
Compliance�½Level
EN61000-4-2, Level�½3,�½8KV
EN61000-4-2, Level�½2,�½4KV
EN61000-4-3, Level�½2,�½3V/m
Level�½3,�½10V/m
EN61000-4-4, Level�½2,�½1KV/5KHz
Level�½3,�½2KV/5KHz
EN61000-4-5, Level�½4,�½2KV/Line-Line
4KV/Line-Earth
EN61000-4-6, Level�½2,�½3Vrms/m
Level�½3,�½10Vrms/m
EN61000-4-8, Level�½2,�½3A/m
Level�½3,�½10A/m
EN61000-4-11,Compliance
ENV50204, Level�½2,�½3V/m,�½900MHz
Level�½3,�½10A/m,�½900MHz
of�½ambient�½�½temperature,
WWW.AstROdYNE.COm
STORAGE�½TEMP.,�½HUMIDITY
-40~+85 ,�½10~90%�½RH
300 myles standish Blvd., taunton, mA 02780
File�½Name:120W�½MEDICAL-SPEC�½�½�½2005-09-13
ph: 1-800-823-8082
Fax: 508-823-8181