1 0 W U l t r a mi ni ature Mod ular Switc hing P ower S uppl ies
INPUT SPECIFICATIONS
Input Voltage, Nominal
Input Frequency
Inrush Current
85-265VAC
Nominal: 100-240VAC
47-440 Hz, 50-60Hz Nom.
20A @ 100VAC, typ
40A @ 200VAC, typ
MCA-10
Open Collector
Logic “1”/Open=ON
Logic “0”/GND=OFF
3000VAC
1000VAC
2500VAC
140 Khz, fixed
75 - 80%, typ
series
GENERAL SPECIFICATIONS
On/Off Control
OUTPUT SPECIFICATIONS
Output Voltage/Current
Initial Accuracy
Voltage Adjust
Load Regulation
Line Regulation
Temperature Coefficient
Ripple/Noise(20Mhz BW)
Overvoltage Protection
Hold Up Time
Short Circuit Protection
Current Limit
See Specific Model
+/-1%, adjustable
+/-6%, typ
+/-0.3%, typ
+/-0.3%, typ
+/-0.03%/°C
150mV Pk-Pk, typ
Clamp, 130-150%
*
30mS, typ
Continuous, self-recovering
*
130% typ,Self-Reset Foldback
Input-Out Isolation
Output-Ground Isolation
Input-Ground Isolation
Operating Frequency
Efficiency (@ Full Load)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Relative Humidity
Storage Temperature
MTBF, Single/Multi Output
0 to +50°C FL See Derate
*
(Free-air Convection)
0-95%, Non-Condensing
-25 to +71°C
*
180,000 Hrs/110,000 Hrs
Mil Std 217, 25C
PHYSICAL SPECIFICATIONS
Case Material
Construction
Weight
Rynite, 94V-0 Rated
Encapsulated, Soft Pot
PCB / CHA
4.6 oz (128g) / 8.5 oz (238g)
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
*
These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181