AUSTIN SEMICONDUCTOR, INC.
Austin Semiconductor, Inc.
Sector Un-Protect Algorithm Flow
START
Protect
all sectors:
The indicated portion
of the
sector
protect
algorithm
must
be
performed for
all
unprotected
sectors
prior to issuing the
first
sector
unprotect
address
AS8FLC2M32
FLASH
PLSCNT = 1
RESET# = V
ID
Wait 1 ms
First Write
Cycle = 60h?
No
Temporary
Sector
Unprotect Mode
Yes
No
All
sectors
protected?
Yes
Set
up first
sector
address
Sector
Unprotect:
Write 60h to
sector
address
with
A7 = 1, A2 = 1,
A1 = 0
Wait 15 ms
Verify
Sector
Unprotect: Write
40h to
sector
address
with
A7 = 1, A2 = 1,
A1 = 0
Read from
sector address
with A7 = 1,
A2 = 1, A1 = 0
Set
up
next
sector
address
Increment
PLSCNT
No
PLSCNT
= 1000?
Yes
No
Data = 00h?
Yes
Device failed
Last
sector
verified?
Yes
No
Sector
Unprotect
Algorithm
Remove V
ID
from RESET#
Write reset
command
Sector
Unprotect
complete
AS8FLC2M32B
Rev. 1.2 5/09
Austin Semiconductor, Inc. reserves the right to change products or specifications without notice.
8