AMMC - 6420
6 - 18 GHz Power Amplifier
Data Sheet
Chip Size: 2000 x 2000
µm
(78.5 x 78.5 mils)
Chip Size Tolerance: ± 10
µm
(±0.4 mils)
Chip Thickness: 100 ± 10
µm
(4 ± 0.4 mils)
Pad Dimensions: 100 x 100
µm
(4 ± 0.4 mils)
Description
AMMC-6420 MMIC is a broadband 1W power amplifier
designed for use in frequency bands between 6 to 18GHz.
It is a cost-effective alternative in commercial communica-
tions systems to a discrete FET hybrid. The MMIC has a
partial input and output match to 50Ω but can be easily
externally matched by single element for narrow band
frequency coverage The MMIC is unconditionally stable
over all frequencies and bias conditions. Gate voltage is
set using the Vg pin to optimize for linear or saturated
power amplification. A temperature compensated RF
output power detector circuit allows differential output
power detection of 0.3V/W at 18 GHz. For improved reli-
ability and moisture protection, the die is passivated at
the active areas.
Features
• Wide frequency range: 6 - 18 GHz
• High gain: 20 dB
• Power: @17 GHz, P-2dB=30.5 dBm
• Highly linear: OIP3=38dBm
• Integrated RF power detector
• 5.5 Volt, -0.6 Volt, 800mA operation
Applications
• Microwave Radio systems
• Satellite VSAT and DBS systems
• LMDS & Pt-Pt mmW Long Haul
• 802.16 & 802.20 WiMax BWA
• WLL and MMDS loops
• Commercial grade military
• Can be driven by AMMC-5618 (6-20 GHz) MMIC
increasing luding overall gain.
AMMC-6420 Absolute Maximum Ratings
[1]
Symbol
V
d
V
g
I
d
P
in
T
ch
T
stg
T
max
Parameters/Conditions
Positive Drain Voltage
Gate Supply Voltage
Drain Current
CW Input Power
Operating Channel Temp.
Storage Case Temp.
Maximum Assembly Temp
(60 sec max)
V
V
mA
Units
Min.
-3
Max.
7
0.5
1500
23
+150
dBm
°C
°C
°C
-65
+150
+300
Note:
1. Operation in excess of any one of these conditions may result in permanent damage to this device.
Note: These devices are ESD sensitive. The following precautions are strongly recommended. Ensure that an ESD
approved carrier is used when dice are transported from one destination to another. Personal grounding is to be worn
at all times when handling these devices.