Switching Specifications
Over recommended operating temperature (T
A
= -40°C to +85°C) unless otherwise specified.
Parameter
Symbol
Min.
Typ.*
Max.
Units
Test Conditions
Input Current Threshold
High to Low
Propagation Delay
Time to High Output
Level
Propagation Delay
Time to Low Output
Level
Pulse Width Distortion
Propagation Delay Skew
Output Rise Time
Output Fall Time
Propagation Delay
Time of Enable
from V
EH
to V
EL
Propagation Delay
Time of Enable
from V
EL
to V
EH
*All typical values at T
A
= 25°C, V
CC
= 5 V.
Fig.
7, 10
9, 11,
12
9, 11,
12
9, 13
24
9, 14
9, 14
Note
18
4, 9,
18
4, 10,
18
17, 18
11, 18
4, 18
4, 18
12
I
THL
t
PLH
1.5
52
3.0
100
mA
ns
V
CC
= 5.5 V, V
O
= 0.6 V,
I
O
>13 mA (Sinking)
I
F
= 3.5 mA
V
CC
= 5.0 V,
V
E
= Open,
C
L
= 15 pF,
R
L
= 350 Ω
t
PHL
53
100
ns
PWD
|t
PHL
- t
PLH
|
t
PSK
t
R
t
F
t
EHL
11
45
60
ns
ns
ns
ns
ns
I
F
= 3.5 mA
V
CC
= 5.0 V,
V
EL
= 0 V, V
EH
= 3 V,
C
L
= 15 pF,
R
L
= 350 Ω
42
12
19
15,
16
15,
16
t
ELH
30
ns
12
Common Mode Transient Immunity Specifications,
All values at T
A
= 25°C
Parameter
Device
Symbol Min.
Typ. Max. Units
Output High
Level Common
Mode Transient
Immunity
HCPL-261A
HCPL-061A
HCPL-263A
HCPL-063A
HCPL-261N
HCPL-061N
HCPL-263N
HCPL-063N
Output Low
Level Common
Mode Transient
Immunity
HCPL-261A
HCPL-061A
HCPL-263A
HCPL-063A
HCPL-261N
HCPL-061N
HCPL-263N
HCPL-063N
|CM
L
|
|CM
H
|
1
5
Test Conditions
V
CC
= 5.0 V,
R
L
= 350 Ω,
I
F
= 0 mA,
T
A
= 25°C
V
O(MIN)
= 2 V
Using Avago
App Circuit
V
CC
= 5.0 V,
R
L
= 350 Ω,
I
F
= 3.5 mA,
V
O(MAX)
= 0.8 V
T
A
= 25°C
Using Avago
App Circuit
Fig.
17
Note
4, 13,
15, 18
kV/µs V
CM
= 50 V
1
15
1
5
25
5
kV/µs V
CM
= 1000 V
kV/µs
kV/µs V
CM
= 50 V
20
17
4, 13,
15
4, 14,
15, 18
1
15
5
25
kV/µs V
CM
= 1000 V
kV/µs
20
4, 14,
15
9