欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-T250 参数 Datasheet PDF下载

HCPL-T250图片预览
型号: HCPL-T250
PDF下载: 下载PDF文件 查看货源
内容描述: 1.5安培输出电流IGBT栅极驱动光电耦合器 [1.5 Amp Output Current IGBT Gate Drive Optocoupler]
分类和应用: 栅极光电输出元件双极性晶体管栅极驱动
文件页数/大小: 7 页 / 233 K
品牌: AVAGO [ AVAGO TECHNOLOGIES LIMITED ]
 浏览型号HCPL-T250的Datasheet PDF文件第2页浏览型号HCPL-T250的Datasheet PDF文件第3页浏览型号HCPL-T250的Datasheet PDF文件第4页浏览型号HCPL-T250的Datasheet PDF文件第5页浏览型号HCPL-T250的Datasheet PDF文件第6页浏览型号HCPL-T250的Datasheet PDF文件第7页  
HCPL-T250
1.5 Amp Output Current IGBT Gate Drive Optocoupler
Data Sheet
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
Description
The HCPL‑T250 contains GaAs LED. The LED is optically
coupled to an integrated circuit with a power output stage.
This optocoupler is ideally suited for driving power IGBTs
and MOSFETs used in motor control inverter applications.
The high operating voltage range of the output stage
provides the drive voltages required by gate controlled
devices. The voltage and current supplied by this optocou‑
pler makes it ideally suited for directly driving IGBTs with
ratings up to 1200 V/25 A. For IGBTs with higher ratings,
the HCPL‑T250 can be used to drive a discrete power stage
which drives the IGBT gate.
Features
Input threshold current (I
FLH
): 5 mA (max.)
Supply current (I
CC
): 11 mA (max.)
Supply voltage (V
CC
): 15‑35 V
Output current (I
O
): ±0.5 A (min.)
Switching time (t
PLH
/t
PHL
): 0.5 µs (max.)
Isolation voltage (V
ISO
): 3750 Vrms (min.)
UL 1577 recognized: File No. E55361
CSA approved
IEC/EN/DIN EN 60747‑5‑2 approved with V
IORM
= 630
V
peak
5 kV/µs Minimum Common Mode Rejection (CMR) at
Vcm = 1500 V
Creepage distance: 7.4 mm
Clearance: 7.1 mm
Functional Diagram
N/C
ANODE
CATHODE
N/C
1
2
3
Q2
4
SHIELD
5
V
EE
Q1
8
7
6
V
CC
V
O
V
O
Applications
IGBT/MOSFET gate drive
AC/brushless DC motor drives
Industrial inverters
Switch mode power supplies
Truth Table
LED
ON
OFF
V
out
HIGH
LOW
A 0.1 µF bypass capacitor must be connected between pins 5 and 8.
CAUTION:
It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.