欢迎访问ic37.com |
会员登录 免费注册
发布采购

AZ2110-1A-70D 参数 Datasheet PDF下载

AZ2110-1A-70D图片预览
型号: AZ2110-1A-70D
PDF下载: 下载PDF文件 查看货源
内容描述: 40A小型功率继电器 [40A MINIATURE POWER RELAY]
分类和应用: 继电器功率继电器
文件页数/大小: 3 页 / 123 K
品牌: AZETTLER [ AMERICAN ZETTLER, INC. ]
 浏览型号AZ2110-1A-70D的Datasheet PDF文件第1页浏览型号AZ2110-1A-70D的Datasheet PDF文件第3页  
AZ2110/AZ2120
RELAY ORDERING DATA
STANDARD RELAYS: UL 508: 1/8” Clearance, 1/4” Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
Nominal
Coil
VDC
Max.
Continuous
VDC
Coil
Resistance
±10%
Must
Operate
VDC
Form A (SPST)
Form C (SPDT)
5
6
9
12
15
18
24
48
70
110
7.3
8.9
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
27
40
97
155
256
380
660
2,560
5,500
13,450
3.75
4.5
6.75
9.0
11.25
13.5
18.0
36.0
52.5
82.5
AZ2110–1A–5D
AZ2110–1C–5D
AZ2110–1A–6D
AZ2110–1C–6D
AZ2110–1A–9D
AZ2110–1C–9D
AZ2110–1A–12D
AZ2110–1C–12D
AZ2110–1A–15D
AZ2110–1C–15D
AZ2110–1A–18D
AZ2110–1C–18D
AZ2110–1A–24D
AZ2110–1C–24D
AZ2110–1A–48D
AZ2110–1C–48D
AZ2110–1A–70D
AZ2110–1C–70D
AZ2110–1A–110D AZ2110–1C–110D
STANDARD RELAYS: 1/16” Clearance, 1/8” Creepage
COIL SPECIFICATIONS
5
6
9
12
15
18
24
48
70
110
7.3
8.9
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
27
40
97
155
256
380
660
2,560
5,500
13,450
3.75
4.5
6.75
9.0
11.25
13.5
18.0
36.0
52.5
82.5
ORDER NUMBER*
AZ2111–1A–5D
AZ2111–1C–5D
AZ2111–1A–6D
AZ2111–1C–6D
AZ2111–1A–9D
AZ2111–1C–9D
AZ2111–1A–12D
AZ2111–1C–12D
AZ2111–1A–15D
AZ2111–1C–15D
AZ2111–1A–18D
AZ2111–1C–18D
AZ2111–1A–24D
AZ2111–1C–24D
AZ2111–1A–48D
AZ2111–1C–48D
AZ2111–1A–70D
AZ2111–1C–70D
AZ2111–1A–110D AZ2111–1C–110D
* Substitute “1B” in place of the “1A” to indicate 1 Form B contact. To indicate Class F version, add suffix “F”. For quick
connect terminals on contacts substitute “2120” or “2121” in place of “2110” or “2111”.
UL/CUR File E44211 Approved Contact Ratings
Load Type
General Purpose
(Inductive)
Resistive
Cycles
100,000
30,000
100,000
100,000
100,000
100,000
6,000
6,000
6,000
30,000
100,000
6,000
100,000
6,000
6,000
30,000
100,000
30,000
100,000
30,000
100,000
Volts
125 or 240 VAC
277 VAC
125 or 240 VAC
30 VDC
277 VAC
240 VAC
250 VAC
277 VAC
125 VAC
125 VAC
125 VAC
240 VAC
277 VAC
125 VAC
240 VAC
125 VAC
125 or 277 VAC
125 VAC
125 VAC
240 VAC
277 VAC
Form A
(NO)
Form B
(NC)
Form C
NO
NC
15 A
30 A
15 A
10 A
3A
290 VA
275 VA
768 VA
1
/
4
HP
1 HP
33 LRA
10 FLA
33 LRA
10 FLA
3A
3A
TV–3
TV–3
Ballast
Pilot Duty
Motor Load
Definite Purpose
(LRA-Locked Rotor)
(FLA-Full Load)
6,000
125 VAC
6,000
240 VAC
6,000
120 VAC
6,000
240 VAC
TV–5
25,000
120 VAC
TV–3
25,000
120 VAC
Note: See AZ2100 Data Sheet for more complete
Tungsten
30 A
15 A
30 A
30 A
30 A
30 A
30 A
15 A
30 A
20 A
10 A
20 A
20 A
15 A
40 A
40 A
6A
3A
6A
800 VA
290 VA
800 VA
800 VA
690 VA
690 VA
470 VA
1152 VA
768 VA
1152 VA
764 VA
764 VA
1
/
4
HP
1 HP
1 HP
3 HP
1 HP
2 HP
1 HP
1 HP
3
/
4
HP
3
/
4
HP
96 LRA
33 LRA
60 LRA
30 FLA
10 FLA
20 FLA
82.8 LRA
82.8 LRA
27 FLA
27 FLA
80 LRA
33 LRA
60 LRA
30 FLA
10 FLA
20 FLA
60 LRA
60 LRA
20 FLA
20 FLA
15 A
15 A
5A
5A
3A
3A
TV–5
TV–5
TV–3
UL and CUR approved contact ratings.
11/30/05W