AZ695
SENSITIVE
SUBMINIATURE RELAY
FEATURES
•
Extremely small footprint utilizing only 0.18 square inch
of PCB area
•
Thin vertical profile only 0.256" wide
•
1 Form A contact with up to 5 Amp switching capability
•
High sensitivity, 100 mW pickup
•
Dielectric strength 3000 Vrms contact to coil
•
Coils to 24 VDC
•
Epoxy sealed for automatic wave soldering
and cleaning
•
UL file E44211; CSA file 74461
CONTACTS
Arrangement
Ratings
SPST (1 Form A)
Resistive load:
Max. switched power: 150 W or 1250 VA
Max. switched current: 5 A
Max. switched voltage: 150* VDC or 250 VAC
Inductive load (p.f. = 0.40, L/R = 7 ms)
2 A at 250 VAC, 30 VDC
UL/CSA Ratings
5 A at 30 VDC resistive
5 A at 250 VAC general use
1
/
10
HP 120 VAC
Note: If switching voltage is greater than 30 VDC, special
precautions must be taken. Please contact the factory.
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Operate Time (typical)
Release Time (typical)
Minimum operations
20 million operations
1 X 10
5
at 5 A, 30 VDC or 250 VAC Res.
6 ms at nominal coil voltage
3 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength
750 Vrms between open contacts
(at sea level for 1 min.)
3000 Vrms contact to coil
Insulation
Resistance
Dropout
Ambient Temperature
Operating
Storage
Vibration
Shock
Enclosure
100 megohms min. at 20°C, 500 VDC,
50% RH
Greater than 10% of nominal coil voltage
At nominal coil voltage
-40°C (-40°F) to 70°C (158°F)
-40°C (-40°F) to 105°C (221°F)
0.062" DA at 10–55 Hz
10 g
P.B.T. polyester
Tinned copper alloy, P.C.
270°C (518°F)
5 seconds
80°C (176°F)
30 seconds
3 grams
Material
Options:
Silver cadmium oxide
Silver cadmium oxide with gold plating
< 30 milliohms initially
(6 V, 1 A, voltage drop method)
Resistance
COIL
Power
At Pickup Voltage
(typical)
Max. Continuous
Dissipation
Temperature Rise
Temperature
100 mW
550 mW at 20°C (68°F) ambient
420 mW at 40°C (104°F) ambient
25°C (45°F) at nominal coil voltage
Max. 105°C (221°F)
Terminals
Max. Solder Temp.
Max. Solder Time
Max. Solvent Temp.
Max. Immersion Time
Weight
NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Minimum permissible contact load:
SCO contact: 100 mA at 5 VDC
SCO contact with gold plating: 10 mA at 5 VDC
4. Specifications subject to change without notice.
7/12/01W