欢迎访问ic37.com |
会员登录 免费注册
发布采购

AZ100LVE210 参数 Datasheet PDF下载

AZ100LVE210图片预览
型号: AZ100LVE210
PDF下载: 下载PDF文件 查看货源
内容描述: ECL / PECL 1 : 4 , 1 : 5差分时钟驱动器 [ECL/PECL 1:4, 1:5 Differential Clock Driver]
分类和应用: 时钟驱动器
文件页数/大小: 5 页 / 72 K
品牌: AZM [ ARIZONA MICROTEK, INC ]
 浏览型号AZ100LVE210的Datasheet PDF文件第2页浏览型号AZ100LVE210的Datasheet PDF文件第3页浏览型号AZ100LVE210的Datasheet PDF文件第4页浏览型号AZ100LVE210的Datasheet PDF文件第5页  
ARIZONA MICROTEK, INC.
AZ100LVE210
ECL/PECL 1:4, 1:5 Differential Clock Driver
FEATURES
PACKAGE AVAILABILITY
Operating Range of 3.0V to 5.5V
PACKAGE
PART NUMBER
MARKING
NOTES
Low Skew
AZM100LVE210
Guaranteed Skew Spec
PLCC 28
AZ100LVE210FN
1,2
<Date Code>
Differential Design
1
Add R2 at end of part number for 13 inch (2.5K parts) Tape & Reel.
V
BB
Output
2
Date code format: “YY” for year followed by “WW” for week.
75kΩ Internal Input Pulldown Resistors
Direct Replacement for ON Semiconductor
MC100LVE210 & MC100E210
DESCRIPTION
The AZ100LVE210 is a low skew 1:4, 1:5 fanout buffer designed with clock distribution in mind. The device
features fully differential clock paths to minimize both device and system skew. The AZ100LVE210 offers two
selectable clock inputs allowing redundant or test clocks to be incorporated into the system clock trees.
The AZ100LVE210 provides a V
BB
output for single-ended use or a DC bias reference for AC coupling to the
device. For single–ended input applications, the V
BB
reference should be connected to one side of the CLKa/CLKb
differential input pair. The input signal is then fed to the other CLKa/CLKb input. The V
BB
should only be used as a
bias for its sink/source capability is limited. When used, the V
BB
pin should be bypassed to ground via a 0.01μF
capacitor.
Both sides of the differential output must be terminated into 50Ω to ensure that the tight skew specification is
met, even if only one side is used. In most applications all eight differential pairs will be used and therefore
terminated. In the case where fewer than eight pairs are used, all output pairs on the same package side (sharing the
same V
CCO
) as the pairs being used should be terminated to maintain minimum skew. Failure to do this will result in
small degradations of propagation delay (on the order of 10–20ps) of the outputs being used; while not being
catastrophic to most designs this will result in an increase in skew.
NOTE: Specifications in the ECL/PECL tables are valid when thermal equilibrium is established.
1630 S. STAPLEY DR., SUITE 127
MESA, ARIZONA 85204
USA
(480) 962-5881
FAX (480) 890-2541
www.azmicrotek.com