TYPICAL PERFORMANCE CURVES
(CONT)
At T
A
= +25°C, V
S
=
±15V,
and R
L
= 10kΩ, unless otherwise noted.
SMALL-SIGNAL STEP RESPONSE
G =1, C
L
= 100pF
SMALL-SIGNAL STEP RESPONSE
G = 1, C
L
= 1000pF
50mV/div
50mV/div
500ns/div
5µs/div
LARGE-SIGNAL STEP RESPONSE
G = 1, C
L
= 100pF
SETTLING TIME vs GAIN
100
0.01%
Settling Time (µs)
5V/div
10
0.1%
1
5µs/div
±1
±10
Gain (V/V)
±100
OUTPUT VOLTAGE SWING vs OUTPUT CURRENT
15
14
Output Voltage Swing (V)
80
70
SMALL-SIGNAL OVERSHOOT
vs LOAD CAPACITANCE
G = +1
13
12
11
10
–10
–11
–12
–13
–14
–15
0
±5
±10
Output Current (mA)
±15
±20
+125°C
+85°C
+25°C
–55°C
+125°C
+25°C
–55°C
Overshoot (%)
60
50
40
30
G = –1
20
10
0
10pF
G = ±5
100pF
1nF
Load Capacitance (F)
10nF
100nF
®
OPA130, 2130, 4130