HDSL Magnetics
GlobeSpan MDSL/HDSL2
•
Designed to meet UL1950 and IEC 950 safety
requirements
Operating temperature range: -40° to +85° C
Meets IEC 695, 2-2 flammability requirements
•
Minimum interwinding breakdown voltage 1500 Vrms
•
TM00313
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning
Reliability testing: shock, vibration, temperature cycling,
temperature - humidity - bias
•
•
•
ELECTRICAL SPECIFICATIONS AT 25° C
Turns Ratio
±2%
Part Number
(1-3) : (2-4) : (7-5) : (8-6)
S560-6600-24
1:1:2:2
DCR
Ω
max
(1-4)
6
(8-5)
7
10
4
60
85
Indcutance
5
mH ±10%
Return
Loss
1
db max
Insertion
Loss
2
db max
Longitudinal
Balance
3
db min
Harmonic
Distortion
4
db min
(1-4)
3.125
1. Measured at 100 kHz to 1 MHz
2. Measured at 1 kHz to 2 Mz
3. Measured at 20 kHz to 1 MHz
4. Measured at 3.5 Vrms, 10 kHz, Rs = 135
Ω
, RL = 33.8
Ω
5. Measured at 10 kHz, connect 2 to 3
DCR
Ω
max
(1-4)
3
(2-5)
3
(9-6)
4
(10-7)
4
10
Turns Ratio
±2%
Part Number
(1-4) : (2-5) : (10-7) : (9-6)
S560-6600-37
1:1:2:2
Return
Loss
1
db max
Insertion Loss
db max
1 kHz -
2 MHz
4
4 kHz -
1 MHz
1.1
Longitudinal
Balance
2
db min
Harmonic
Distortion
3
db min
60
85
1. measured at 100 kHz to 200 kHz
2. measured at 20 kHz to 1 MHz
3. measured at 10 kHz
SCHEMATIC
S560-6600-37
S560-6600-24
1
4
2
5
10
7
9
6
1
8
3
2
6
7
4
5
©2001Bel Fuse Inc. Specifications subject to change without notice. 06.01
Bel Fuse Inc.
206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
T3-43