B8
Series
4. Triple Output Selection Guide:
:
Bothhand
Model No.
Input
Voltage
(Vdc)
Output
Voltage
(Vdc)
Output
Current
(mA) Max
10 to 15 Watt Isolated DC-DC Converter
Triple Output
( Specifications typical at Ta = +25
℃,
Nominal input voltage, Rated output current unless otherwise noted )
Input Current
@ No Load
(mA) Typ.
Input Current
@ Max. Load
(mA) Typ.
Output
Ripple
(mV) Max.
Load
Regulation
(%) Max.
Efficiency
(%) Typ.
10 W Triple output Series
:
B8-1212T10
9 ~ 18
B8-1215T10
B8-2412T10
18 ~ 36
B8-2415T10
B8-4812T10
36 ~ 72
B8-4815T10
5.0
± 15
1000 ± 167
15
261
75
±8
80
15W Triple output Series
:
B8-1212T15
9 ~ 18
B8-1215T15
B8-2412T15
18 ~ 36
B8-2415T15
B8-4812T15
36 ~ 72
B8-4815T15
B8-xxxxTxx
Notes:
1.
2.
5.0
5.0
5.0
5.0
5.0
± 12
± 15
± 12
± 15
± 12
1000 ± 209
1000 ± 167
1000 ± 209
1000 ± 167
1000 ± 209
35
40
28
25
18
1070
1043
522
521
258
75
75
75
75
75
±8
±8
±8
±8
±8
78
80
80
80
81
5.0
5.0
5.0
5.0
5.0
5.0
± 12
± 15
± 12
± 15
± 12
± 15
1500 ± 313
1500 ± 250
1500 ± 313
1500 ± 250
1500 ± 313
1500 ± 250
37
45
30
27
20
17
1604
1563
782
781
391
391
75
75
75
75
75
75
±8
±8
±8
±8
±8
±8
78
80
80
80
80
80
B8-xxxxTxx is for Customer Design.
Suffix “H” for 3K Vdc Isolation. ( B8-xxxxTxxH )
Mechanical
:
( Triple O/P )
Units : mm ( inch )
Tolerance : .xx ± 0.25
( ± 0.01 )
BOTHHAND USA. http://www.bothhand.com