Reliability Test  
Classification  
Test Item  
Reference Standard  
Test Conditions  
Result  
Operation Life MIL-STD-750:1026  
MIL-STD-883:1005  
Connect with a power If=20mA  
Ta=Under room temperature  
Test time=1,000hrs  
0/20  
JIS-C-7021  
:B-1  
Ta=+65±5℃  
High  
Temperature MIL-STD-202:103B  
RH=90%-95%  
0/20  
High Humidity JIS-C-7021  
:B-11 Test time=240hrs  
Endurance  
Test  
Storage  
High  
Temperature  
Storage  
Low  
High Ta=+85±5℃  
MIL-STD-883:1008  
JIS-C-7021 :B-10  
Test time=1,000hrs  
0/20  
0/20  
Low Ta=-35±5℃  
Temperature JIS-C-7021  
Storage  
:B-12 Test time=1,000hrs  
-35~ +25~ +85~ +25℃  
60min 20min 60min 20min  
Test Time=5cycle  
Temperature MIL-STD-202:107D  
Cycling  
MIL-STD-750:1051  
MIL-STD-883:1010  
0/20  
0/20  
0/20  
JIS-C-7021  
:A-4  
-35±5~+85±5℃  
Thermal Shock MIL-STD-202:107D  
MIL-STD-750:1051  
Environmental  
Test  
20min  
20min  
MIL-STD-883:1011  
Test Time=10cycle  
Preheating:  
140-160,within 2 minutes.  
Operation heating:  
260(Max.), within 10seconds. (Max.)  
Solder  
MIL-STD-202:201A  
Resistance  
MIL-STD-750:2031  
JIS-C-7021  
:A-1  
Judgment criteria of failure for the reliability  
Measuring items  
Forward voltage  
Reverse current  
Luminous intensity  
Symbol  
VF ( V)  
Measuring conditions  
IF=20mA  
Judgement criteria for failure  
Over Ux1.2  
IR(uA)  
VR=5V  
Over Ux2  
Iv ( mcd )  
IF=20mA  
Below SX0.5  
Note: 1.U means the upper limit of specified characteristics. S means initial value.  
2.Measurment shall be taken between 2 hours and after the test pieces have been returned to  
normal ambient conditions after completion of each test.  
Ver.1.0 Page 5 of 7