欢迎访问ic37.com |
会员登录 免费注册
发布采购

HB50-12-25N 参数 Datasheet PDF下载

HB50-12-25N图片预览
型号: HB50-12-25N
PDF下载: 下载PDF文件 查看货源
内容描述: 12VIN 2.5 ,3.3 ,5.0 ,12,15 , 24Vout 50W [12Vin 2.5, 3.3, 5.0, 12, 15, 24Vout 50W]
分类和应用:
文件页数/大小: 8 页 / 264 K
品牌: BTCPOWER [ BROADBAND TELCOM POWER, INC. ]
 浏览型号HB50-12-25N的Datasheet PDF文件第1页浏览型号HB50-12-25N的Datasheet PDF文件第2页浏览型号HB50-12-25N的Datasheet PDF文件第3页浏览型号HB50-12-25N的Datasheet PDF文件第4页浏览型号HB50-12-25N的Datasheet PDF文件第5页浏览型号HB50-12-25N的Datasheet PDF文件第6页浏览型号HB50-12-25N的Datasheet PDF文件第8页  
Technical Specification
HB50-12 Series
12Vin 2.5, 3.3, 5, 12, 15, 24Vout 50W
BTCPower
TM
Protection Features
Input Under-voltage lockout ( IUV )
Input under voltage ( IUV ) is standard with the
HB unit. The unit will shut down when the input
voltage drops below a threshold, and the unit will
turn on when the input voltage goes to the upper
threshold.
The hysteretic voltage of the under voltage
protection is 0.5V, normally from the 8.8V to 8.2V
range in typical
Output Over-current Protection ( OCP )
The unit will shut down when the over current or
short circuit condition exists.
Once the OCP happens, the unit has shut down.
The attempted restart will continue indefinitely
until the over current or short circuit condition is
removed. When OCP happens, the output
voltage drops below 1.0V.
Input voltage has almost no effect on the current
limit point.
Output Over-voltage Prote ction ( OVP )
The unit will shut down when the output voltage
exceeds the over voltage threshold.
If the output voltage across Vout(+) (pin9) and
Vout(-) (pin5) exceeds the threshold of the OVP
circuitry, the unit has shut down which is caused
by an OVP circuit, and the unit will never restart,
and the output voltage is below 0.5V.
Over Temperature Protection ( OTP )
The unit will shut down when the base plate
temperature exceeds the protection threshold.
The unit will shut down under the base plate
temperature over a 105°C condition to protect the
unit from overheating. The OTP circuit will turn
the unit off when OTP happens. Once the unit
has shut down, it will restart at the cycle when the
base plate temperature goes down.
Broadband TelCom Power, Inc.
1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A.
P
7 of 8
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com •
PS HB 50-12 Rev2 16-1-04