Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
C
omlinear
CLC1008, CLC1018, CLC2008
0.5mA, Low Cost, 75MHz Rail-to-Rail Amplifiers
Parameter
Supply Voltage
Input Voltage Range
Continuous Output Current
Min
0
-V
s
-0.5V
-30
Max
6
+V
s
+0.5V
30
Unit
V
V
mA
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
5-Lead SOT23
6-Lead SOT23
8-Lead SOIC
8-Lead MSOP
Notes:
Package thermal resistance (q
JA
), JDEC standard, multi-layer test boards, still air.
Min
-65
Typ
Max
175
150
260
Unit
°C
°C
°C
°C/W
°C/W
°C/W
°C/W
221
177
100
139
Recommended Operating Conditions
Parameter
Operating Temperature Range
Supply Voltage Range
Min
-40
2.5
Typ
Max
+85
5.5
Unit
°C
V
Rev 2A
©2009-2011 CADEKA Microcircuits LLC
www.cadeka.com
3