CLM2805
CORPORATION
ADJUSTABLE
PARAMETERS
V
IN
= 14V, V
O
= 3V, I
O
= 10mA, R
1
= 27k, C
2
= 100µF, T
J
= 25
o
C
CLM2805A/C
UNITS
MIN
1.14
TYP
1.20
MAX
1.26
V
1.08
1.32
I
o
≤
120mA, over Tem. R
1
= 27K
CONDITIONS
Reference Voltage
ADJUSTABLE VERSION ONLY
PARAMETERS
V
IN
= 14V, V
O
= 3V, I
O
= 10mA, R
1
= 27k, C
2
= 100µF, T
J
= 25
o
C
CLM2805C
UNITS
MIN
TYP
MAX
24
0.2
0.3
40
0.4
1.0
mA
1.0
µVrms/V
%/1000h
%/V
0.2
0.6
V
I
O
= 10mA, Reference Voltage <1.5V
V
O
>0.3V, R
L
= 500Ω
1% Duty Cycle, T<100ms, R
L
= 500Ω
50
1.2
V
V
O
= 3V
µA
f
O
= 120Hz
I
O
= 10mA
I
O
= 120mA
1.5
1.0
V
mV
% max
mΩ/V
V
OUT
+0.6V<V
IN
<26V
5mA<I
O
<100mA
100mA DC and 10mA rms, 100Hz - 10kHz
I
O
= 10mA
I
O
= 120mA
During Shutdown R
L
= 500Ω
10Hz - 100kHz
3.0
CONDITIONS
Output Voltage Range
Line Regulation
Load Regulation
Output Impedance
Quiescent Current
15
0.8
Output Noise Voltage
Long Term Stability
Ripple Rejection
Dropout Voltage
100
0.4
0.02
0.05
0.3
Maximum Operational Input Voltage
Maximum Line Transient
Reverse Polarity Input Voltage, DC
Reverse Polarity Input Voltage, Transient
On/Off Threshold Current
Threshold Voltage On
Threshold Voltage Off
26
60
-15
-50
33
70
-30
-80
20
2.0
3.25
2.2
Notes:
1. See TYPICAL APPLICATIONS notes to ensure constant junction temperature, low duty cycle pulse testing used.
2. All limits are at 125
o
C or over the full operating temperature junction range of -40
o
C to +125
o
C.
3. The maximum power dissipation is a function of maximum junction temperature, total thermal resistance and ambient temperature.
4. Human body model, 100µF discharged through 1.5KΩ.
CALOGIC CORPORATION,
237 Whitney Place, Fremont, California 94539, Telephone: 510-656-2900, FAX: 510-651-3025