ELECTRICAL CHARACTERISTICS
Specifications typical at T
A
= +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
(VDC)
5
5
5
5
12
12
12
15
15
RATED
OUTPUT
VOLTAGE
(VDC)
5
±5
±12
±15
5
±12
±15
5
±15
RATED
OUTPUT
CURRENT
(mA)
1000
±500
±208
±167
1000
±208
±167
1000
±167
INPUT CURRENT
NO LOAD
RATED LOAD
(mA)
70
70
70
70
25
25
25
20
20
(mA)
1250
1250
1190
1190
490
490
490
407
392
REFLECTED
RIPPLE
CURRENT
(mAp-p)
15
15
15
15
15
15
15
15
15
EFFICIENCY
(%)
80
80
84
84
80
85
85
82
85
MODEL
HPR700
HPR703
HPR704
HPR705
HPR706
HPR710
HPR711
HPR712
HPR717
Note: Other input to output voltage options may be available. Please consult factory.
COMMON SPECIFICATIONS
Specifications typical at T
A
= +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
INPUT
Voltage Range
CONDITIONS
MIN
TYP
MAX
UNITS
V
DC
V
DC
V
DC
Voltage Rise Time
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
Voltage
4.75
5
5.25
11.4
12
12.6
14.2
15
15.8
See Application Note: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
60 Hz, 10 seconds
500
500
1
55
5
V
ISO
= 240VAC, 60Hz
V
DC
Vpk
GW
pF
µArms
Rated Load, Nominal V
IN
BW = DC to 10MHz
BW =10Hz to 2MHz
I
L
=10mA, V
OUT
= 5V
I
L
=10mA, V
OUT
= ±12V
I
L
=10mA, V
OUT
= ±15V
5
±3
±0.05
50
5
5.75
13.10
16.25
W
%
%/Deg C
mVp-p
mVrms
V
DC
V
DC
V
DC
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
TEMPERATURE
Specification
Operation
Storage
High Line to Low Line
Rated Load to No Load
Rated Load to No Load
1.2
15
10
%/%Vin
%
%
170
7
Circuit Stress Method
T
A
= +25°C
2000
kHz
g
kHr
-25
-40
-40
+25
+70
+85
+110
°C
°C
°C
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation.......................................................................1.7W
Short Circuit Protection..................................................................Momentary
Lead Temperature (soldering, 10 seconds max)................................+300°C
ORDERING INFORMATION
HPR
Device Family
HPR indicates DC/DC converter
Model Number
Screening Option
7XX
/H
Page 2
HPR7XX
REV B
6/98