ABSOLUTE MAXIMUM RATINGS
PARAMETER
Repetitive Peak Off State Voltage
RMS on State Current
Non Repetitive Peak on State Current
l t for Fusing
Repetitive Rate of Rise of On State
Current After Triggering
Peak Gate Current
Peak Gate Power
Average Gate Power
Storage Temperature
Operating Junction Temperature
2
SYMBOL
V
DRM
I
T (RMS)
I
TSM
I
2
t
dl
T
/dt
I
GM
P
G M
P
G (AV)
T
stg
T
j
VALUE
600
4.0
25
3.1
50
2.0
5.0
0.5
- 40 to 150
125
UNIT
V
A
A
A
2
s
A/µs
A
W
W
ºC
ºC
ELECTRICAL CHARACTERISTICS (T
J
=25ºC unless specified otherwise)
PARAMETER
Gate Trigger Current
SYMBOL
TEST CONDITION
I
GT
V
D
=12V, I
T
=0.1A
I
II
III
IV
I
H
V
D
=12V, I
GT
=0.1A
V
GT
V
T
I
D
V
D
=12V, I
T
=0.1A
I
T
=5A
V
DRM
=600V
MIN
MAX
10
10
10
25
20
1.5
1.7
0.5
UNIT
mA
mA
mA
mA
mA
V
V
mA
Holding Current
Gate Trigger Voltage
On State Voltage
Off State Leakage Current
BT136X_600ERev021104E