PS9552,PS9552L1,PS9552L2,PS9552L3
ELECTRICAL CHARACTERISTICS (T
A
=
−40
to +100°C, V
CC
= 15 to 30 V, I
F (ON)
= 7 to 16 mA,
V
F (OFF)
=
−2
to 0.8 V, V
EE
= GND, unless otherwise specified)
Parameter
Diode
Forward Voltage
Input Capacitance
Detector High Level Output Current
Symbol
V
F
C
IN
I
OH
Conditions
I
F
= 10 mA, T
A
= 25°C
f = 1 MHz, V
F
= 0 V, T
A
= 25°C
V
O
= (V
CC
−
4 V)
*2
MIN.
1.3
TYP.
*1
MAX.
2.1
Unit
V
pF
A
1.65
60
0.5
*3
2.0
V
O
= (V
CC
−
15 V)
Low Level Output Current
I
OL
2.0
0.5
2.0
V
CC
−
3.5 V
CC
−
2.5 V
CC
−
1.5
0.1
2.0
2.0
11.0
9.5
12.3
10.7
1.6
2.0
5.0
0.5
5.0
5.0
13.5
12.0
V
mA
V
V
mA
mA
V
2.0
A
V
O
= (V
EE
+ 2.5 V)
V
O
= (V
EE
+ 15 V)
*2
*3
High Level Output Voltage
Low Level Output Voltage
High Level Supply Current
V
OH
V
OL
I
CCH
I
CCL
V
UVLO+
V
UVLO−
I
O
=
−100
mA
I
O
= 100 mA
*4
V
O
= open, I
F
= 7 to 16 mA
V
O
= open, V
F
=
−2
to +0.8 V
V
O
> 5 V, I
F
= 10 mA
<R>
Low Level Supply Current
UVLO Threshold
UVLO Hysteresis
Coupled Threshold Input Current
(L
→
H)
UVLO
HYS
V
O
> 5 V, I
F
= 10 mA
I
FLH
I
O
= 0 mA, V
O
> 5 V
<R>
Threshold Input Voltage
(H
→
L)
V
FHL
I
O
= 0 mA, V
O
< 5 V
0.8
V
*1
Typical values at T
A
= 25°C.
*2
Maximum pulse width = 50
μ
s, Maximum duty cycle = 0.5%.
*3
Maximum pulse width = 10
μ
s, Maximum duty cycle = 0.2%
*4
V
OH
is measured with the DC load current in this testing (Maximum pulse width = 2 ms, Maximum duty cycle =
20%).
Data Sheet PN10589EJ03V0DS
7