 浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第8页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第9页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第10页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第11页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第12页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第13页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第15页浏览型号ZICM2410P0-1-SN的Datasheet PDF文件第16页  
MeshConnect™ Module Series  
PROCESSING (Continued)  
Hand Soldering  
Hand soldering is possible. Use a soldering iron temperature setting equivalent to 350°C, follow IPC recommendations/  
reference document IPC-7711.  
Rework  
The MeshConnect Module can be unsoldered from the host board. Use of a hot air rework tool and hot plate for pre-heating  
from underneath is recommended. Avoid overheating.  
Warning Never attempt a rework on the module itself, e.g. replacing individual components. Such actions will  
terminate warranty coverage.  
Additional Grounding  
Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield cover is  
done at the customer's own risk. The numerous ground pins at the module perimeter should be sufficient for optimum  
immunity to external RF interference.  
AGENCY CERTIFICATIONS  
FCC Compliance Statement (Part 15.19) Section 7.15 of RSS-GEN  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause undesired operation.  
Warning (Part 15.21)  
Changes or modifications not expressly approved by CEL could void the user's authority to operate the equipment.  
20 cm Separation Distance  
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this  
transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located  
or operating in conjunction with any other antenna or transmitter.  
OEM Responsibility to the FCC Rules and Regulations  
The MeshConnect Module has been certified per FCC Part 15 rules for integration into products without further testing or  
certification. To fulfill the FCC certification requirements, the OEM of the MeshConnect Module must ensure that the  
information provided on the MeshConnect Label is placed on the outside of the final product. The MeshConnect Module is  
labeled with its own FCC ID Number. If the FCC ID is not visible when the module is installed inside another device, then  
the outside of the device into which the module is installed must also display a label referring to the enclosed module. This  
exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: W7Z-ICP0” or “Contains FCC  
ID: W7Z-ICP0”  
The OEM of the MeshConnect Module must only use the approved antenna, (PCB Trace Antenna) that has been certified  
with this module. The OEM of the MeshConnect Module must test their final product configuration to comply with Uninten-  
tional Radiator Limits before declaring FCC compliance per Part 15 of the FCC rules.  