I/SEC/AC11-001/A/12/05/2002
page 1 / 2 F/GB
INTERRUPTEUR REED
REED SWITCH
NORMALEMENT OUVERT, CONTACT SEC
NORMALY OPEN, DRY CONTACT
Ø 2 max
AC11 . . . .
Ø 0,4
10 max
35,7
CARACTERISTIQUES ELECTRIQUES /
ELECTRICAL DATA
Puissance maxi commutable /
Max. switching power
Tension maxi commutable /
Max. switching voltage
Courant maxi commutable /
Max. switching current
Courant de travail /
Carrying current
Tension typique de tenue /
Typical dielectric strength
1 VA
24 Vdc
0,1 A
0,3 A
150 Vdc
Résistance de contact initiale ( max ) /
Initial contact resistance
Méthode de mesure /
Test process
Bobine /
Coil
:
Mesure en 4 points /4
points measurement
I = 10 mA ; U = 2 V
Alimentation de bobine /Coil
voltage:
ATF + 20 %
≤
150 mΩ
mesure de tension
voltage measurement
30 mm
Résistance d'isolement ( min ) /
Insulation resistance
Capacité /
Capacitance
Fréquence de résonnance /
Resonnant frequency
109
Ω
0,2 pF
7500 Hz
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.