欢迎访问ic37.com |
会员登录 免费注册
发布采购

CM2596S_06 参数 Datasheet PDF下载

CM2596S_06图片预览
型号: CM2596S_06
PDF下载: 下载PDF文件 查看货源
内容描述: 3A降压稳压器 [3A STEP DOWN VOLTAGE REGULATOR]
分类和应用: 稳压器
文件页数/大小: 13 页 / 401 K
品牌: CHAMP [ CHAMPION MICROELECTRONIC CORP. ]
 浏览型号CM2596S_06的Datasheet PDF文件第5页浏览型号CM2596S_06的Datasheet PDF文件第6页浏览型号CM2596S_06的Datasheet PDF文件第7页浏览型号CM2596S_06的Datasheet PDF文件第8页浏览型号CM2596S_06的Datasheet PDF文件第10页浏览型号CM2596S_06的Datasheet PDF文件第11页浏览型号CM2596S_06的Datasheet PDF文件第12页浏览型号CM2596S_06的Datasheet PDF文件第13页  
CM2596S
3A S
TEP
D
OWN
V
OLTAGE
R
EGULATOR
Output Voltage Ripple and Transients
The output ripple voltage is due mainly to the inductor sawtooth ripple current multiplied by the ESR of the output capacitor. The
output ripple voltage of a switching power supply will contain a sawtooth ripple voltages at the switcher frequency, typically about
1% of the output voltages, and may also contain short voltage spikes of the sawtooth waveform.
Due to the fast switching action, and the parasitic inductance of the output filter capacitor, there is voltage spikes presenting at
the peaks of the sawtooth waveform. Cautions must be taken for stray capacitance, wiring inductance, and even the scope
probes used for transients evaluation. To minimize these voltage spikes, shortening the lead length and PCB traces is always the
first thought. Further more, an additional small LC filter (30uH & 100uF) (as shown in Figure 3) will possibly provide a 10X
reduction in output ripple voltage and transients.
7V-40V
DC INPUT
Cin
470uF
L1
68uH
3uF
Cout
220uF
Inductor Selection
The CM2596S can be used for either continuous or discontinuous modes of operation. Each mode has distinctively different
operating characteristics, which can affect the regulator performance and requirements.
With relatively heavy load currents, the circuit operates in the continuous mode (inductor current always flowing), but under light
load conditions, the circuit will be forced to the discontinuous mode (inductor current falls to zero for a period of time). For light
loads (less than approximately 300mA) it may be desirable to operate the regulator in the discontinuous mode, primarily because
of the lower inductor values required for the discontinuous mode.
Inductors are available in different styles such as pot core, toriod, E-frame, bobbin core, et., as well as different core materials,
such as ferrites and powdered iron. The least expensive, the bobbin core type, consists of wire wrapped on a ferrite rod core.
This type of construction makes for an inexpensive inductor, but since the magnetic flux is not completely contained within the
core, it generates more electromagnetic interference (EMI). This EMI can cause problems in sensitive circuits, or can give
incorrect scope readings because of induced voltages in the scope probe.
An inductor should not be operated beyond its maximum rated current because it may saturate. When an inductor begins to
saturate, the inductance decreases rapidly and the inductor begins to look mainly resistive (the DC resistance of the winding).
This will cause the switch current to rise very rapidly. Different inductor types have different saturation characteristics, and this
should be well considered when selecting as inductor.
2006/11/27 Rev 1.0
Champion Microelectronic Corporation
Page 9