RATINGS AND CHARACTERISTIC CURVES MBRX120 THRU MBRX160
Figure 3
Forward Derating Curve
1.2
60
50
1.0
40
.8
Amps
.6
Amps
10
.4
0
.2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
75
100
°C
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -°C
125
150
175
1
2
4
8 10
Cycles
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
20
40
60 80 100
30
20
Figure 4
Peak Forward Surge Current
0
FIG. 5 - TYPICAL REVERSE
CHARACTERISTICS
100
INSTANTANEOUS REVERSE CURRENT,
MILLIAMPERES
10
T
J
=125°C
1
0.1
T
J
=75°C
0.01
T
J
=25°C
0.001
0
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
MDD ELECTRONIC