2/11
DATA SHEET
3. Outline drawing - Marking
Unit : mm
Tolerances unless otherwise specified : +/-0.3
Cathode
Protection
(Tc Measurement Point)
×3
×3
×3
×3
×3
Anode
Cathode
Anode
Marking 1 : Serial No.
Marking 2 :
#
Resin area (including white resin)
CRI
CCT
Dies in parallel quantity
Dies in series quantity
CLL012
4. Performance
(1) Absolute Maximum Rating
Parameter
Symbol
Rating Value
Unit
Input Power
Forward Current
Mnimum current
6.7
600
25
*1
*1
Pi
IF
IF min
IR
Top
Tst
W
mA
mA
mA
C
Reverse Current
1
-30 ~ +85
-40 ~ +100
Operating Temperature
Storage Temperature
Case Temperature
Junction Temperature
C
100
140
*2
*3
Tc
Tj
C
C
*1 Input power and forward current are the values when the LED is used within the range of
the derating curve in this data sheet.
*2 Refer to 3. Outline drawing for Tc measurement point
*3 D.C. Current : Tj = Tc + Rj-c X Pi
Symbol
Name
CITILED
CLL012-0305A5-50KL1A1
CITIZEN ELECTRONICS CO.,LTD. JAPAN
Ref.CE-P2233 03/13 R1(1013)