CLL Series
Photo-IC Sensors
Digital Output
0.500(12.7) min.
0.500(12.7) min.
0.157 (3.99)
0.210 (5.33)
0.137 (3.48)
0.210 (5.33)
0.190 (4.83)
0.190 (4.83)
0.187 (4.75)
0.187 (4.75)
0.179
0.179 (4.55)
(4.55)
1. OUTPUT
1. OUTPUT
2. VCC
2. VCC
4
®
Clairex
Technologies, Inc
.
March
, 2003
3. GROUND
3. GROUND
4. ADJUST
4. ADJUST
0.048 (1.22)
0.048 (1.22)
0.028 (0.71)
0.028 (0.71)
0.046 (1.17)
0.046 (1.17)
0.036 (0.91)
0.036 (0.91)
4
3
TO-72
CLL130
CLL131
CLL133
3
2
2
1
1
0.030 (0.76) max.
0.030 (0.76) max.
0.060 (1.52)
0.060 (1.52) max
max
0.230 (5.84)
0.230 (5.84)
0.209 (5.31)
0.209 (5.31)
45°
45°
Case 21
1. OUTPUT
0.500(12.7) min.
0.210 (5.33)
0.190 (4.83)
4
3
0.187 (4.75)
0.179 (4.55)
2
1
0.030 (0.76) max.
0.010 (0.25) max
0.046 (1.17)
0.036 (0.91)
0.230 (5.84)
0.209 (5.31)
0.048 (1.22)
0.028 (0.71)
2. VCC
3. GROUND
4. ADJUST
TO-72
CLL130W
CLL131W
CLL133W
45°
Case 22
1. OUTPUT
0.500(12.7) min.
3. GROUND
4. ADJUST
features
Output stages:
a. Buffer or inverter
b. Open collector or internal
10KΩ pull-up
Supply voltage 4.5V to 18V
7:1 user sensitivity adjustment
on CLL130-CLL133 and
CLL130W-CLL133W series
Acceptance angle:
a. ± 15° high dome lens can
b. ± 35° flat window lens can
Operates to 125°C
RoHS compliant
description
The CLL series are monolithic
integrated circuits incorporating a
photodiode, linear amplifier, Schmitt
trigger for hysteresis and pulse
shaping, and digital output with either
10KΩ pull-up or open collector. The
series includes TO-72 four leaded
packages (with user adjustable gain)
and TO-18 three leaded packages in
both high dome and flat window
configurations. Alternate pin-outs
are available. Contact Clairex.
0.210 (5.33)
0.190 (4.83)
2. VCC
4
3
0.187 (4.75)
0.179 (4.55)
0.048 (1.22)
0.028 (0.71)
TO-18
CLL134
CLL135
CLL136
CLL137
2
1
0.030 (0.76) max.
0.060 (1.52) max
0.046 (1.17)
0.036 (0.91)
0.230 (5.84)
0.209 (5.31)
45°
Case 21
1. OUTPUT
0.500(12.7) min.
0.210 (5.33)
0.190 (4.83)
4
3
0.187 (4.75)
0.179 (4.55)
2
1
0.030 (0.76) max.
0.010 (0.25) max
0.046 (1.17)
0.036 (0.91)
0.230 (5.84)
0.209 (5.31)
0.048 (1.22)
0.028 (0.71)
2. VCC
3. GROUND
4. ADJUST
TO-18
CLL134W
CLL135W
CLL136W
CLL137W
45°
Case 22
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS)
Revised 3/16/06
Page 1 of 4
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Plano, Texas 75074-8524
www.clairex.com