CPC1030N
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Capacitance
Input to Output
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
(10 Seconds Max.)
1
2
Min
-
-
-
-
-
-
1500
-40
-40
Typ Max Units
- 150
1
mW
-
50
mA
-
1
A
-
5
V
2
mW
- 400
1
-
-
-
-
pF
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
-
V
RMS
+85
°C
+125 °C
+220 °C
Derate Linearly 1.33 mw / oC
Derate Linearly 6.67 mw / oC
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current (Continuous)
AC Peak 1
Peak Load Current
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
1
2
3
Conditions
-
Symbol
V
L
I
L
Min
-
-
-
-
-
-
-
-
2
0.3
0.9
-
-
Typ
-
-
-
25
-
-
25
-
0.9
1.2
-
-
Max
350
120
350
30
1
2
1.0
-
50
-
1.4
5
10
Units
V
mA
mA
Ω
µA
ms
ms
pF
mA
mA
V
V
µA
10ms
I
L
=120mA
V
L
=350V
I
F
=5mA, V
L
=10V
I
F
=5mA, V
L
=10V
50V; f=1MHz
I
L
=120mA
-
I
F
=5mA
-
V
R
=5V
I
LPK
R
ON
I
LEAK
T
ON
T
OFF
C
OUT
I
F
I
F
V
F
V
R
I
R
Load current derates linearly from 120mA @ 25oC to 80mA @ 85oC.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 10mA is recommended.
2
www.clare.com
Rev. 5