CPC1831
Absolute Maximum Ratings
Parameter
Reverse Voltage
Operational Temperature
Storage Temperature
Ratings
10
-40 to +85
-40 to +125
Units
V
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Open Circuit Voltage
Short Circuit Current
Conditions
Direct Sun (6000 lux)
High Intensity Lamp
Direct Sun (6000 lux)
Symbol
V
OC
V
OC
I
SC
Min
-
-
-
Typ
7.3
7.8
25
Max
-
-
-
Units
V
V
μA
PERFORMANCE DATA*
Normalized Open Circuit Output Voltage
vs. Light Intensity
4.0
Normalized Output Voltage
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
0
2
4
6
8
Light Intensity (lux X 1000)
10
Normalized Output Current
Normalized Short Circuit Output Current
vs. Light Intensity
2.50
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0.00
0
2
4
6
8
Light Intensity (lux X 1000)
10
Normalized Open Circuit Output Voltage
vs. Incident Angle of light
to Photodiode Surface
1.2
Normalized Output Voltage
Normalized Output Current
1.0
0.8
0.6
0.4
0.2
0.0
0
20
40
60
80
Incident Angle (Degrees)
100
Normalized Short Circuit Output Current
vs. Incident Angle of Light
to Photodiode Surface
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
20
40
60
80
Incident Angle (Degrees)
100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
2
www.clare.com