CPC1963
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation
1
Total Package Dissipation
2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
2
Ratings Units
600
V
P
5
V
50
mA
1
A
150
mW
800
mW
3750
V
rms
-40 to +85
°C
-40 to +125
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Derate linearly 1.33 mW / ºC
Derate linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise
3
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
1
Operating Frequency
Load Power Factor for Guaranteed Turn-On
2
Input Characteristics
Input Control Current
4
Input Drop-out Voltage
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
1
2
Conditions
V
T
V
L
=120V
rms
V = 600V
I
L
=500 mA
rms
-
Symbol
-
I
L
I
LEAK
V
ON
dV/dt
t
on
t
off
-
PF
I
F
V
F
I
R
C
I/O
Min
20
0.005
-
-
1000
-
-
-
-
20
0.25
-
0.8
0.9
-
-
Typ
-
-
-
-
-
-
-
2
1
-
-
0.23
-
1.2
-
3
Max
260
0.5
1
1.4
-
0.5
0.5
10
-
500
-
5
-
1.4
10
-
Units
V
rms
A
rms
mA
V
rms
V/µs
I
F
=5 mA
1st half-cycle
Subsequent half-cycle
-
-
-
-
I
F
=5mA
V
R
=5V
-
cycles
V
Hz
-
mA
V
V
µA
pF
Zero Cross 1st half-cycle @ <100Hz
Snubber circuits may be required at low power factors.
3
Tested in accordance with EIA/NARM standard RS-443.
4
For high noise environments use at least 10mA LED current.
2
www.clare.com
R05