LCA120
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1
2
Min
-
-
-
-
-
3750
-40
-40
-
-
Typ Max Units
-
-
-
-
-
-
-
-
-
-
150
1
50
1
5
800
2
-
+85
+125
+260
+220
mW
mA
A
V
mW
V
RMS
°C
°C
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure of
the device to the absolute maximum ratings for an extend-
ed period may degrade the device and effect its reliability.
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current (Continuous)
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
I
L
=Load Current
-
I
F
=5mA
-
V
R
=5V
-
-
I
F
I
F
V
F
V
R
I
R
C
I/O
V
I/O
5
0.4
0.9
-
-
-
3750
-
0.7
1.2
-
-
3
-
50
-
1.4
5
10
-
-
mA
mA
V
V
µA
pF
V
RMS
-
-
-
10ms
I
L
=Load Current
I
L
=Load Current
V
L
=25OV
I
F
=5mA, V
L
=10V
I
F
=5mA, V
L
=10V
50V; f=1MHz
V
L
I
L
I
L
I
LPK
R
ON
I
LEAK
T
ON
T
OFF
C
OUT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15
5
-
-
-
50
250
150
200
-
20
6
1
3
3
-
V
mA
mA
mA
Ω
Ω
µA
ms
ms
pF
Conditions
Symbol
Min
Typ
Max
Units
2
www.clare.com
Rev. 8