PAA140L
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Blocking Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Flatpack/Surface Mount
Package
(10 Seconds Max.)
1
2
Min
-
-
-
-
-
-
3750
-40
-40
-
-
Typ Max Units
-
-
-
-
-
-
-
-
-
-
-
150
1
50
1
5
400
800
2
mW
mA
A
V
V
mW
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
-
V
RMS
°
C
+85
+125
°
C
+260
+220
°
C
°
C
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Current* (Continuous)
AC/DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Load Current Limit
Output Capacitance
Capacitance
Input to Output
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
-
10ms
I
L
=200mA
V
L
=400V
I
F
=5mA, V
L
=10V
I
F
=5mA, V
L
=10V
I
F
=5mA
50V; f=1MHz
-
I
L
= 200mA
-
I
F
= 5mA
-
V
R
=5V
-
I
L
I
LPK
R
ON
I
LEAK
T
ON
T
OFF
I
CL
C
OUT
-
I
F
I
F
V
F
V
R
I
R
C
I/O
-
-
-
-
-
-
240
-
-
5
0.4
0.9
-
-
-
-
-
10
-
-
-
-
65
3
-
0.7
1.2
-
-
3
200
500
13
1
5.0
3.0
380
-
-
50
-
1.4
5
10
-
mA
mA
Ω
µA
ms
ms
mA
pF
pF
mA
mA
V
V
µA
pF
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
2
www.clare.com
Rev 1.0