PBB150
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min
Typ Max Units
-
-
-
-
-
-
-
-
-
-
-
150
1
50
1
5
800
2
mW
mA
A
V
mW
Input Power Dissipation
-
Input Control Current
-
Peak (10ms)
-
Reverse Input Voltage
-
Total Power Dissipation
-
Isolation Voltage
Input to Output
3750
Operational Temperature
-40
Storage Temperature
-40
Soldering Temperature
-
DIP Package
-
Flatpack/Surface Mount Pkg -
(10 Seconds Max.)
1
2
Absolute Maximum Ratings are stress ratings. Functional
operation of the device at these or any other conditions
beyond those indicated in the operational sections of this
data sheet is not implied. Exposure of the device to the
absolute maximum ratings for an extended period may
degrade the device and effect its reliability.
-
V
RMS
°
C
+85
+125
°
C
-
-
+260
°
C
+220
°
C
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
Electrical Characteristics
PARAMETER
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current* (Continuous)
AC/DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
CONDITIONS
-
-
10ms
I
L
=250mA
V
L
=250mA
I
F
=5mA, V
L
=10V
I
F
=5mA, V
L
=10V
50V; f=1MHz
I
L
= 250mA
-
I
F
= 5mA
-
V
R
=5V
-
-
SYMBOL
V
L
I
L
I
LPK
R
ON
I
LEAK
T
ON
T
OFF
C
OUT
I
F
I
F
V
F
V
R
I
R
C
I/O
V
I/O
MIN
-
-
-
-
-
-
-
-
5
0.4
0.9
-
-
-
3750
TYP
-
-
-
-
-
-
-
110
-
0.7
1.2
-
-
3
-
MAX
250
250
500
7
1
2.5
2.5
-
50
-
1.4
5
10
-
-
UNITS
V
mA
mA
Ω
µA
ms
ms
pF
mA
mA
V
V
µA
pF
V
RMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
2
www.clare.com
Rev. 3