PLA134
Performance Data*
35
30
Device Count (N)
25
20
15
10
5
0
PLA134
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
I
F
= 5mADC
25
20
15
10
PLA134
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 350mADC; I
F
= 5mADC)
PLA134
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
25
20
15
10
5
0
Device Count (N)
5
0
2.2
2.25
2.3
2.35
2.4
2.45
On-Resistance (Ω)
Device Count (N)
1.17
1.19
1.21
1.23
1.25
100
110
120
130
140
150
LED Forward Voltage Drop (V)
Blocking Voltage (V)
PLA134
Typical I
F
for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 350mADC)
25
20
15
10
5
0
0.75
1.05
1.35
1.65
1.95
2.25
LED Current (mA)
PLA134
Typical I
F
for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 350mADC)
25
20
15
10
5
0
0.75
1.05
1.35
1.65
1.95
2.25
LED Current (mA)
25
20
15
10
PLA134
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 350mADC; I
F
= 5mADC)
Device Count (N)
Device Count (N)
Device Count (N)
5
0
0.9
0.15
0.21
0.27
.33
.39
Turn-On (ms)
25
20
15
10
PLA134
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 350mADC; I
F
= 5mADC)
Load Current (mA)
PLA134
Typical Load Current vs. Temperature
AC/DC Configuration
600
Load Current (mA)
PLA134
Typical Load Current vs. Temperature
DC Configuration
900
800
700
600
500
400
300
200
100
0
500
400
300
200
100
0
Device Count (N)
10mA
5mA
10mA
5mA
5
0
0.075
0.085
0.095
0.105
Turn-Off (ms)
-40
-20
0
20
40
60
80
100
120
-40
-20
0
20
40
60
80
100
120
Temperature (°C)
Temperature (°C)
PLA134
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
0.018
Blocking Voltage (V
RMS
)
0.016
0.014
Leakage (µA)
0.012
0.01
0.008
0.006
0.004
0.002
0
-40
-20
0
20
40
60
80
100
Temperature (°C)
PLA134
Typical Blocking Voltage vs. Temperature
175
150
PLA134
Typical Turn-On vs. Temperature
(Load Current = 200mADC)
0.7
0.6
Turn-On (ms)
0.5
0.4
0.3
0.2
0.1
5mA
125
100
75
50
25
0
-40
-20
0
20
40
60
80
100
Temperature (°C)
0
-40
-20
0
20
40
60
80
100
Temperature (°C)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications,
please contact our application department.
Rev. 2
www.clare.com
3