Input Frequency Selection
Table 4
Input Freq
f
1
f
2
f
3
f
4
SEL A
0
0
1
1
SEL B
0
1
0
1
Output Load and Power Supply Filtering Recommendations
Figure 2
*
*
*
*
It is highly recommended
that either a linear regulator
or bypass capacitors be
used. Typical values would
be 10 uF, 0.1 uF, 100 pF.
V
T
-2 V
DC
LD
(Pin 3)
470 kΩ
Monitor
(Pin 4)
50Ω
50Ω
CLKIN
(Pin 1)
Frequency
Divider
Loop
Filter
PECL
VCXO
OUT
(Pin 9)
COut
(Pin 10)
(F
OUT
)
Frequency
10 kΩ
Divider
Select A
(Pin 12)
Microprocessor
10 kΩ
Select B
(Pin 13)
Enable/Disable
(Pin 8)
Data Sheet #:
SG076
Page 4
of
8
Rev:
00
Date:
4/11/07
© Copyright 2007 The Connor-Winfield Corp. All Rights Reserved
Specifications subject to change without notice