Ele c tronic — PCB & Sm a ll Dim e ns ion Fus e s
5 x 20m m Europe a n (IEC) fe rrule fus e s
S500-V (GDB-V)* (a xia l le a ds )
S500 (GDB)*
S501-V (GDA-V)* (a xia l le a ds )
S506-V (GDC-V)* (a xia l le a ds )
S501 (GDA)*
S506 (GDC)*
Spe c ific a tions
De s c ription: Fast-
acting, low-breaking
capacity fuse.
Spe c ific a tions
Spe c ific a tions
De s c ription: Time-
delay, low-breaking
capacity fuse.
De s c ription: Fast-
acting, high-break-
ing capacity fuse.
Cons truc tion:
Glass tube, nickel-
plated brass end-
caps.
Cons truc tion:
Ceramic tube, nick-
el-plated brass end-
caps.
Cons truc tion:
Glass tube, nickel-
plated brass end-
caps.
Ra tings :
Ra tings :
Ra tings :
Volts — 250Vac (or less)
Amps — 32mA-16A
IR — See catalog table
Volts — 250Vac (or less)
Amps — 50mA-10A**
IR — 1500A @ 250Vac
Volts — 250Vac (or less)
Amps — 32mA-15A**
IR — 35A @ 250Vac
Age nc y Inform a tion: CE, Designed to
IEC 60127-Sheet II British Standard
Approval SEMKO Approval VDE
Approval, IMQ UL Recognized, Guide
JDYX2, File E19180, 32mA-6.3A.
Age nc y Inform a tion: CE, UL
Recognized, SEMKO Approval,
VDE Approval.
Age nc y Inform a tion: UR, CSA,
SEMKO, VDE, BSI, IMQ, PSE, CCC.
See data sheet for complete agency
information.
See data sheet for complete agency
information.
Fe a ture s a nd Be ne fits
• Time-delay compatibility for inductive
circuits.
Fe a ture s a nd Be ne fits
Fe a ture s a nd Be ne fits
• Fast-acting for maximum protection,
conforms to IEC standards.
• Fast-acting for maximum protection.
• High break capacity for use in higher
fault energy electronic circuitry.
• Conforming to IEC standards.
• Conforming to IEC standards.
Typic a l Applic a tions
• Electronic Circuits
Typic a l Applic a tions
• Electronic Circuits
Typic a l Applic a tions
• Electronic Circuits
Ca ta log Num be rs (Am ps )
Ca ta log Num be rs (Am ps )
Ca ta log
IR
Ma x Volta ge
Drop (m V)
Ca ta log
Typic a l
2
Ma x Volta ge
Drop (m V)
2
I t
Num be rs
(Am ps )
Num be rs
I t
Ca ta log Num be rs (Am ps )
S500-32-R
S500-40-R
S500-50-R
S500-63-R
S500-80-R
S500-100-R
S500-125-R
S500-160-R
S500-200-R
S500-250-R
S500-315-R
S500-400-R
S500-500-R
S500-630-R
S500-800-R
S500-1-R
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
50
63
80
100
0.000047
0.00011
0.00020
0.00057
0.0012
0.003
0.005
0.008
0.016
0.028
0.058
0.018
0.018
0.035
0.067
0.60
3200
2500
2400
2000
1200
1100
1000
2000
1700
1400
1300
1100
220
Ca ta log
Num be rs
Typic a l Volta ge
Drop (m V)
S506-32-R
S506-40-R
S506-50-R
S506-63-R
S506-80-R
S506-100-R
S506-125-R
S506-160-R
S506-200-R
S506-250-R
S506-315-R
S506-400-R
S506-500-R
S506-630-R
S506-800-R
S506-1-R
0.0051
0.0072
0.0095
0.021
0.038
0.045
0.063
0.093
0.114
0.265
0.621
0.872
0.827
1.33
1050
920
800
760
580
490
390
320
340
270
250
210
140
150
75
2
I t
S501-50-R
S501-63-R
S501-80-R
S501-100-R
S501-125-R
S501-160-R
S501-200-R
S501-250-R
S501-315-R
S501-400-R
S501-500-R
S501-630-R
S501-800-R
S501-1-R
0.0017
0.0005
0.0011
0.0018
0.0037
0.008
0.020
0.027
0.010
0.018
0.038
0.064
0.097
0.146
0.313
0.748
2.0
9000
3300
2600
2300
1900
1600
1350
1300
1400
1200
1050
1200
490
220
140
2.78
6.45
10.05
21.7
31.6
200
87.5
86
82
330
297
239
205
S500-1.25-R
S500-1.6-R
S500-2-R
0.84
200
S506-1.25-R
S506-1.6-R
S506-2-R
S501-1.25-R
S501-1.6-R
S501-2-R
1.6
190
4.2
150
77
S500-2.5-R
S500-3.15-R
S500-4-R
6.1
150
S506-2.5-R
S506-3.15-R
S506-4-R
59.4
96.4
71.8
72.5
68.5
67
S501-2.5-R
S501-3.15-R
S501-4-R
3.9
8.1
14
190
160
160
13
130
22
42
69
-
130
S500-5-R
120
S506-5-R
S506-6.3-R
S506-8-R
S506-10-R
S506-12.5-R
S506-15-R
142.5
237.6
255.8
450
1019.5
1091.7
60.5
54
55
54
45
S501-5-R
25
155
S500-6.3-R
S500-8*-R
S500-10*-R
120
S501-6.3-R
S501-8-R
S501-10-R
48
N/A
N/A
150
N/A
N/A
120
—-
120
*IEC Standard 127 Sheet II does not include ratings above 6.3A.
65.5
Options
Options
Axial leads, put “V” in P/N.
*GDA series is not available in RoHS
compliant construction.
Options
Axial leads, put “V” in P/N.
*GDC is not available above 6.3A.
**GDC series is not available in RoHS
compliant construction.
Axial leads, put “V” in P/N,
*S500 Series is the new RoHS compliant version of
the GDB. Please contact Customer Satisfaction for
GDB ordering information.
**GDB series is not available in RoHS compliant
construction.
**GDA is not available above 6.3A.
Da ta She e t: 2014
Da ta She e t: 2016 (GDC), 4332 (S506)
Da ta She e t: 2015 (GDB)
For product data sheets, visit www.cooperbussmann.com/datasheets/ULCSA
55