High Current, High Frequency, Power Inductors
FLAT-PAC™ FP1107 Series
• Current range from 18 amps to 140 amps
• Frequency range up to 2MHz
• RoHS compliant
Applications:
Multi-phase regulators
Voltage Regulator Module (VRM)
Desktop and server VRMs and EVRDs
Data networking and storage systems
Notebook regulators
Graphics cards and battery power systems
Point-of-load modules
DCR sensing
SMD Device
Description:
Halogen free
125°C maximum total temperature operation
7.2 x 11.0 x 7.5mm surface mount package
Ferrite core material
High current carrying capacity, Low core losses
Controlled DCR tolerance for sensing circuits
Inductance range from 70nH to 510nH
Environmental Data:
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C
(Range is application specific)
• Solder reflow temperature: J-STD-020D compliant
Packaging:
• Supplied in tape and reel packaging, 640 parts per reel,
13” diameter reel
Product Specifications
Part Number
7
OCL ± 10% (nH) FLL Min. (nH)
70
120
150
230
300
400
510
70
120
150
230
300
400
510
50
86
108
166
217
288
364
50
86
108
166
217
288
364
1
2
Irms
3
(Amps) Isat1
4
@ 25°C (Amps) Isat2
5
@ 125°C (Amps) DCR (mΩ) @ 20°C K-factor
6
140
90
70
45
35
25
18
140
90
70
45
35
25
18
123
72
56
36
28
20
14.5
123
72
56
36
28
20
14.5
361.1
361.1
361.1
361.1
361.1
361.1
361.1
363.3
363.3
363.3
363.3
363.3
363.3
363.3
R1 Version
FP1107R1-R07-R
FP1107R1-R12-R
FP1107R1-R15-R
FP1107R1-R23-R
FP1107R1-R30-R
FP1107R1-R40-R
FP1107R1-R51-R
R2 Version
FP1107R2-R07-R
FP1107R2-R12-R
FP1107R2-R15-R
FP1107R2-R23-R
FP1107R2-R30-R
FP1107R2-R40-R
FP1107R2-R51-R
55
0.29 ± 10%
42
0.47 ± 6.4%
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
4 Isat1: Peak current for approximately 20% rolloff at +25°C.
5 Isat2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L *
ΔI
* 10-3, Bp-p : (Gauss),
K: (K-factor from table), L: (inductance in nH),
ΔI
(peak-to-peak ripple current in amps).
7 Part Number Definition: FP1107Rx-Rxx-R
• FP1107 = Product code and size
• Rx is the DCR indicator
• Rxx= Inductance value in
μH,
R = decimal point • “-R” suffix = RoHS compliant