High Current, Power Inductors
HCM0703 Series
Applications
•
•
•
•
•
•
•
•
•
Voltage Regulator Module (VRM)
Multi-phase regulators
Point-of-load modules
HF
Pb
FREE
HALOGEN
Desktop and server VRMs and EVRDs
Base station equipment
Notebook regulators
Battery power systems
Graphics cards
Data networking and storage systems
SMD Device
Description
•
•
•
•
•
•
•
•
•
Halogen Free
125°C maximum total temperature operation
7.4 x 7.0 x 3.0mm maximum surface mount package
Powder iron core material
Magnetically shielded, low EMI
High current carrying capacity, Low core losses
Inductance range from 0.15μH to 10.0μH
Current range from 3.2 to 52 Amps
RoHS compliant
Environmental Data
• Storage temperature range: -55°C to +125 °C
• Operating temperature range: -55°C to +125°C
(ambient plus self-temperature rise)
• Solder reflow temperature: J-STD-020D compliant
Packaging
• Supplied in tape and reel packaging, 1,500 parts per
13” diameter reel
Product Specifications
Part
Number
6
HCM0703-R15-R
HCM0703-R22-R
HCM0703-R47-R
HCM0703-R68-R
HCM0703-R82-R
HCM0703-1R0-R
HCM0703-1R5-R
HCM0703-2R2-R
HCM0703-3R3-R
HCM0703-4R7-R
HCM0703-6R8-R
HCM0703-8R2-R
HCM0703-100-R
OCL (μH)
±20%
0.15
0.22
0.47
0.68
0.82
1.00
1.50
2.20
3.30
4.70
6.80
8.20
10.0
1
FLL min,
(μH)
0.09
0.13
0.28
0.41
0.49
0.60
0.90
1.32
1.98
2.82
4.08
4.92
6.00
2
Irms
3
(Amps)
26.0
23.0
17.5
15.5
13.0
11.0
9.00
8.00
6.00
5.50
4.50
4.00
3.20
Isat
4
@ 20°C
(Amps)
52.0
40.0
26.0
25.0
24.0
22.0
18.0
14.0
13.5
10.0
8.00
7.50
7.00
DCR (mΩ) @ 20°C DCR (mΩ) @ 20°C
(Typical)
1.90
2.50
4.00
5.00
6.70
9.00
14.0
18.0
28.0
37.0
54.0
64.0
70.5
(Maximum)
2.50
2.80
4.20
5.50
8.00
10.0
15.0
20.0
30.0
40.0
60.0
68.0
77.6
K-factor
5
1610.3
615.4
430.2
367.4
286.2
259.7
175.7
163.6
158.2
118.1
106.8
95.3
81.2
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.25Vrms, 0.0Adc, @ +20°C.
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.25Vrms, Isat @ +20°C.
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB layout, trace thickness and width, air-flow and proximity of other
heat generating components will affect the temperature rise. It is recommended that the
temperature of the part not exceed 125°C under worst case operating conditions verified in the
end application.
4 Isat: Peak current for approximately 20% rolloff at +20°C.
5 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L *
ΔI.
Bp-p (Gauss),
K: (K-factor from table), L: (inductance in
μH), ΔI
(peak-to-peak ripple current in amps).
6 Part Number Definition: HCM0703-xxx-R
• HCM0703 = Product code and size
• xxx= Inductance value in
μH,
R = decimal point,
If no R is present then 3
rd
digit equals number of zeros.
• “-R” suffix = RoHS compliant
1209
BU-SB091169
Page 1 of 4
Data Sheet: 4085