Receiver Protectors
VDU1838 Pre-TR Limiter
Features:
•
Frequency: 16.8 to 18.0 GHz
•
Peak Power Handling:
- Normal Operating: 600 W
- Overload: 3 kW (100 mS)
•
Pulsewidth: 70 uSec max
•
Duty Cycle: 0.12 max
•
Insertion Loss:
@ + 25
o
C -- 1.4 dB max
@ + 85
o
C – 2.0 dB max
•
VSWR: 1.4:1 max
•
Flat Leakage: 32 mW max
•
Spike Leakage: 200 mW max
•
Recovery Time: 0.6 uSec max
•
Phase Matching: +/- 10 Degrees
•
Step Attenuator: 15 to 18 dB
•
Switching Speed: 700 nS max
•
Excess Noise Ratio: 15 +/- 1.5 dB
Description:
Ku-Band Pre-TR Limiter with integral attenuation
and excess noise generation functions.
150 Sohier Road
Beverly, Massachusetts 01915
Beverly Microwave Division
cp
Phone: 978-922-6000 Fax: 978-922-2736
E-Mail: marketing@bmd.cpii.com
Internet: www.cpii.com/bmd