CPI UnIgrId
PUlSed I-J Band HelIx T W T
SerIeS
CPI | 4CW50,000J
Unigrid Pulsed I-J Band Helix TWT Series
Unigrid-pulsed TWT Series, I-J Band, periodic-perma-
nent, magnet focused, coaxial input, waveguide output,
conduction cooled.
Custom configurations are also available. These varia-
tions in the performance and configuration include:
mechanical configuration, electrical and RF connections,
and dual-stage depressed collector.
FeaTUreS
• 6.0 - 6.5, 6.6 to 18.0 GHz
• Unigrid-Pulsed
• PPM Focusing
• Coaxial Input
•
Waveguide Output
• Any Mounting Position
• Weight: 7 lbs. max
• Conduction Cooled
FreqUenCy
PoWer oUTPUT
(gHz)
(mIn)
VTU-5192F1 6.0 - 6.5 1.41 kW
6.6 - 18.0
1.5 kW
model
TyPICal oPeraTIng ParameTerS
maxImUm
Heater Voltage:
Heater Surge Current:
Helix Voltage:
Helix Current:
Beam Current:
Collector Voltage :
grid gate Voltage:
grid Bias Voltage:
rF drive Power:
Beam duty:
Pulse Width:
Cathode Warm-up Time:
Baseplate Temp:
load VSWr:
ambient Temp (oper):
ambient Temp (non-oper):
6.6
7.0
12.2
500
2.0
eW
250
-250
25
0.04
125
---
100
2.0:1
+85
+110
mInImUm
6.0
---
10.8
---
---
7.3
125
-200
---
---
---
5
---
---
-54
-54
TyPICal
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
UnITS
V
a
kVdc
ma
a
kVdc
v
Vdc
dBm
du
µsec
minutes
°C
VSWr
°C
°C
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information
on this and other CPI products, visit our website at:
www.cpii.com,
or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303
telephone
:
1(800) 414-8823.
fax
:
(650) 856-0705 |