欢迎访问ic37.com |
会员登录 免费注册
发布采购

VZA-6906C5 参数 Datasheet PDF下载

VZA-6906C5图片预览
型号: VZA-6906C5
PDF下载: 下载PDF文件 查看货源
内容描述: 400W / 500W Millitron高功率放大器 [400W/500W Millitron High Power Amplifier]
分类和应用: 放大器功率放大器
文件页数/大小: 2 页 / 201 K
品牌: CPI [ COMMUNICATIONS & POWER INDUSTRIES, INC. ]
 浏览型号VZA-6906C5的Datasheet PDF文件第1页  
Ka-B an d
SPECIFICATIONS, VZA-6906C5
Electrical
Frequency
Output Power
Millitron (standard version)
Millitron (high power version)
Flange (standard version)
Flange (high power version)
Bandwidth
Gain
RF Level Adjust
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
Input VSWR
Output VSWR
Load VSWR
Residual AM
Custom frequency ranges between
28.35 and 31.00 GHz
400 W min. (56.02 dBm)
500 W min. (56.99 dBm)
320 W min. (55.05 dBm)
400 W min. (56.02 dBm)
1000 MHz instantaneous max.
68 dB min. at rated average power;
70 dB typ. at small signal
0 to 30 dB typ.
±0.25 dB/24hr max.
(at constant drive and temp.)
0.05 dB/MHz max.
3.0 dB pk-pk across any 250 MHz band;
3.5 dB pk-pk across the 1000 MHz band
1.3:1 max.
1.3:1 max.
2.0 max. operational; any value for operation
without damage
-50 dBc below 10 kHz
-20 (1.5 +log F kHz) dBc,
10 kHz to 500 kHz
-85 dBc above 500 kHz
Exceeds IESS-308/309 by 10 dB
-36 dBc
-47 dBc (370 Hz to 1 MHz)
2.5°/dB max. for a single carrier at
7 dB below rated power (at 3 dB below
rated power with linearizer)
-30 dBc at rated power, second and third
harmonics
<-150 dBW/4 kHz below 21.2 GHz
<-96 dBW/4 kHz in passband
<-50 dBc above 31 GHz
Shock
Vibration
Acoustic Noise
Heat Dissipation
Power Factor
Electrical (continued)
Intermodulation
-24 dBc max. with two equal
carriers at total output power
7 dB OBO (3 dB OBO with optional
integral linearizer)
Group Delay
(in any 40 MHz band)
Linear
0.03 ns/MHz max.
Parabolic
0.02 ns/MHz sq. max.
Ripple
2.0 ns pk-pk max.
Primary Power
Power Consumption
180-264 VAC, 47-63 Hz
1.7 kVA, typ.
2.5 kVA, max.
0.95 min.
OPTIONS:
• Remote Control Panel
• Integrated Linearizer
• Integrated 1:1 Switch
Control and Drive
• Redundant and Power
Combined Subsystems
• Other frequency ranges
• Ethernet Interface
• Integrated L-Band Block
Upconverter (BUC)
Environmental (Operating)
Ambient Temperature
Relative Humidity
Altitude
-40°C to +50°C operating,
-30°C to +70°C non-operating
100% condensing
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
20 g pk, 11 msec, 1/2 sine pulse
2.1 g
rms
; 5-500 Hz
65 dBA @ 3 ft. from amplifier
1500 watts, max.
Phase Noise
Single Carrier
AC fundamentals related
Sum of Spurs
AM/PM Conversion
Mechanical
Cooling (TWT)
RF Input Connection
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
Forced air with integral blower
WR-28G waveguide
WR 34 waveguide with
UG-1530/U flange (WR-28 optional)
2.9 mm coax, female
14.5 x 13.1 x 24.0
(368 x 333 x 610)
91 lbs with no options (41.4 kg)
Harmonic Output
Noise and Spurious
(at rated gain)
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note:
Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 172, ISSUE 8
01/08