Crane Aerospace & Electronics Power Solutions
MFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
PINS NOT IN USE
PIN OUT
Pin
1
2
Single Output
Dual Output
TR1
Leave unconnected
Leave unconnected
Leave unconnected
Connect to input common
Positive Input
Input Common
Triple (TRI)
Positive Input
Input Common
Triple (TRI)
Master
Slave
Sync in
3
4
5
6
7
8
9
10
11
12
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Sense Return
Positive Sense
Slave
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Negative Output
No connection
Slave
Inhibit (INH1)
Inhibit (INH2)
Sync Out
Leave unconnected
Leave unconnected
Leave unconnected
Must be connected to
appropriate outputs
Sense Lines
Master / Inhibit 2
(MSTR/INH2)
Master / Inhibit 2
(MSTR/INH2)
Angled corner indicates pin one.
1
2
12
11
10
9
TOP VIEW
MFLHP
(Pin side, marked side)
3
4
5
6
8
See case U for dimensions.
7
FIGURE 1: PIN OUT
Page 3 of 11
www.craneae.com
Rev D - 20070703