Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
1
OUTPUT CURRENT
2
OUTPUT POWER
OUTPUT RIPPLE
VOLTAGE +V
OUT
–V
OUT
LINE REGULATION
LOAD
3
REGULATION , 4
3
MGH2805D
MIN
±4.95
±4.80
0
0
—
—
—
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
73
70
—
—
—
—
–300
–400
—
—
–250
–300
—
—
—
—
—
—
TYP
±5
±5
±150
—
35
50
35
50
10
20
300
350
80
100
—
28
—
5.0
6.0
69
72
2.3
2.4
100
130
77
75
1.4
1.6
3.7
3.8
130
140
100
100
125
130
0.6
0.6
8
10
0
0
MAX
±5.05
±5.20
240
1.5
150
250
150
250
50
100
600
700
200
300
400
50
80
10
12
73
77
3.2
3.5
200
250
—
—
2.2
2.5
15
20
300
400
400
500
250
300
2.5
3.0
25
45
100
150
MIN
±11.88
±11.52
0
0
—
—
—
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
73
70
—
—
—
—
–600
–700
—
—
–500
–600
—
—
—
—
—
—
MGH2812D
TYP
±12
±12
±62.5
—
35
40
35
40
100
110
550
570
115
130
—
28
—
7.5
8.0
70
71
2.3
2.4
115
150
77
75
2.5
2.7
3.2
3.2
250
260
165
165
240
250
0.9
0.9
8
10
0
0
MAX
±12.12
±12.48
100
1.5
150
250
150
250
300
400
1100
1200
250
350
500
50
80
13
14
73
77
3.2
3.5
200
250
—
—
3.8
4.2
15
20
600
700
700
800
500
600
3.0
4.0
25
45
250
350
MGH2815D
MIN
±14.85
±14.40
0
0
—
—
—
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
72
69
—
—
—
—
–600
–700
—
—
–500
–600
—
—
—
—
—
—
TYP
±15
±15
±50
—
30
35
30
35
165
180
600
630
125
135
—
28
—
7.5
8.0
71
72
2.3
2.4
90
120
76
74
2.7
3.0
4.0
4.0
250
270
50
50
220
230
0.6
0.7
8
10
0
0
MAX
±15.15
±15.60
80
1.5
150
250
150
250
500
650
1300
1400
300
400
500
50
70
13
14
74
78
3.2
3.5
200
250
—
—
4.1
4.5
15
20
600
700
200
300
500
600
3.0
4.0
25
45
750
900
mA p-p
%
W
ms
mV pk
μs
mV pk
ms
ms
mV pk
mA
V
mV p-p
UNITS
VDC
mA
W
CONDITIONS
Tc = 25°C
Tc = –55°C TO +125°C
V
IN
= 12 to 50 VDC
V
IN
= 12 to 50 VDC
10 kHz - 2 MHz
Tc = –55°C TO +125°C
10 kHz - 2 MHz
Tc = –55°C TO +125°C
VIN = 12 to 50 VDC
Tc = –55°C TO +125°C
10% TO FULL LOAD
–55°C TO +125°C
50% TO FULL LOAD
–55°C TO +125°C
mV
CROSS
REGULATION
5
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
–V
OUT
mV
VDC
V
CONTINUOUS
TRANSIENT 120 ms
NO LOAD
Tc = –55°C TO +125°C
FULL LOAD
Tc = –55°C TO +125°C
INHIBITED
Tc = –55°C TO +125°C
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
6
10 kHz - 10 MHz
Tc = –55°C TO +125°C
Tc = 25°C
Tc = –55°C TO +125°C
7,8
POWER DISSIPATION
Tc = –55°C TO +125°C
RECOVERY
Tc = –55°C TO +125°C
STEP LOAD
RESPONSE
9
± V
out
50 %–100%– 50%
STEP LINE
RESPONSE
19
± V
out
12 TO 50 TO 12 V
IN
START–UP
0 TO 28 VDC, ± V
out
TRANSIENT
Tc = –55°C TO +125°C
RECOVERY
–55°C TO +125°C
TRANSIENT
Tc = –55°C TO +125°C
RECOVERY
Tc = –55°C TO +125°C
DELAY
Tc = –55°C TO +125°C
OVERSHOOT
Tc = –55°C TO +125°C
Notes:
1. Specified at 50% load.
2. Max. spec indicates 80% of the converter’s total available power. This 80%
is available from either output.
3. Specification applies to both + and –Vout.
4. Although no minimum load is required, at no load the output voltage may
increase up to 15%.
5. Cross regulation is specified as the effect on –Vout for the following percent
ages of total output power: +Po = 20% and
–Po = 80% to +Po=80% and –Po=20%
6. Lin = 2 μH.
7. Max. duration of short circuit: 25°C – 90 seconds; 125°C – 30 seconds.
8. Load fault is a short circuit (<50 mohms). Recovery into resistive full load.
9. Input step transition ≥ 10 μs.Recovery is time to settle to within 1% of Vout
final value.
www.craneae.com
Page 10 of 18
Rev E - 20060508